Optimizing electrochemical glucose sensors through electrode material selection and parameter tuning for enhanced sensitivity in diabetes detection

This study presents the development of a highly sensitive and reliable electrochemical glucose sensor tailored for blood biosensing applications. Through comprehensive simulations and comparative analysis of various electrode materials, we systematically evaluated different combinations to identify the most effective material configurations. Performance enhancements were achieved by fine-tuning critical parameters, including temperature, electrode thickness, impedance, and average current density. Our results highlight Palladium Hydride (Pd-H) and Platinum Aluminide (PtAl2) as exceptional performers. Under optimized conditions—temperatures of 310 K and 350 K, with an electrode thickness of 30 µm—the electrochemical glucose sensor demonstrated remarkable sensitivities of 6.024 A·dm3/mol·m2 and 6.465 A·dm3/mol·m2 for Pd-H, and 5.814 A·dm3/mol·m2 and 6.023 A·dm3/mol·m2 for PtAl2, respectively. These findings not only deepen our understanding of electrochemical glucose sensors but also provide valuable insights for the design of customized biosensors tailored for blood glucose monitoring. The identified optimal conditions offer a promising pathway for the development of highly sensitive and specific diagnostic tools for blood glucose level monitoring.

Authors

Institutions

Publication Details

Journal
Discover Electronics
Published
2025-03-13
DOI
https://doi.org/10.1007/s44291-025-00051-4
Citations
4
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
2.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing electrochemical glucose sensors through electrode material selection and parameter tuning for enhanced sensitivity in diabetes detection

R. P. Prajapati, Deepak Punetha, Satvik Noutya
4 citations
Discover Electronics
Electrochemical sensors and biosensors
2.92
article

Optimizing electrochemical glucose sensors through electrode material selection and parameter tuning for enhanced sensitivity in diabetes detection

R. P. Prajapati, Deepak Punetha, Satvik Noutya
article en
4 citations

Abstract

This study presents the development of a highly sensitive and reliable electrochemical glucose sensor tailored for blood biosensing applications. Through comprehensive simulations and comparative analysis of various electrode materials, we systematically evaluated different combinations to identify the most effective material configurations. Performance enhancements were achieved by fine-tuning critical parameters, including temperature, electrode thickness, impedance, and average current density. Our results highlight Palladium Hydride (Pd-H) and Platinum Aluminide (PtAl2) as exceptional performers. Under optimized conditions—temperatures of 310 K and 350 K, with an electrode thickness of 30 µm—the electrochemical glucose sensor demonstrated remarkable sensitivities of 6.024 A·dm3/mol·m2 and 6.465 A·dm3/mol·m2 for Pd-H, and 5.814 A·dm3/mol·m2 and 6.023 A·dm3/mol·m2 for PtAl2, respectively. These findings not only deepen our understanding of electrochemical glucose sensors but also provide valuable insights for the design of customized biosensors tailored for blood glucose monitoring. The identified optimal conditions offer a promising pathway for the development of highly sensitive and specific diagnostic tools for blood glucose level monitoring.

Discover ElectronicsVol. 2(1)
Motilal Nehru National Institute of Technology (IN)
Motilal Nehru National Institute of Technology Allahabad
Openalex Percentile: Top 10%
Electrochemical sensors and biosensors
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.