Bending Flexibility of Negative Poisson's Ratio Structural Vascular Stent

A negative Poisson's ratio structural vascular stent with arrow-shaped cell is proposed in the paper. In order to improve the bending flexibility of the stent, three shapes of connecting bars, namely, U-shaped, S-shaped, and linear, are designed. The influence of structural parameters of the stent connecting bars on the bending performance of the stent is studied using the finite element method and experimental method. The research results show that compared to S-shaped stents, U-shaped stents have better bending flexibility. In addition, the influence of the parameters of the connection bars of a U-shaped stent on its flexibility is also explored. The longer the length of the U-shaped connection bars, the lower the corresponding bending stiffness and better bending flexibility. The larger the width of the U-shaped connecting bar, the greater the bending stiffness of the stent, and the worse its bending flexibility. And some experiments are conducted using the four points bending method. The deformation of the S-shaped stent and U-shaped stent under bending is very similar, and the bending stiffness of the U-shaped stent is lower than that of the S-shaped bracket, which also verified the correctness of the finite element calculation.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanical Engineering
Published
2025-03-13
DOI
https://doi.org/10.1115/1.4068156
Citations
1
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bending Flexibility of Negative Poisson's Ratio Structural Vascular Stent

Mohan Yang, Yao Du, Dongmei Zhu, Guoyong Liu et al.
1 citations
Journal of Biomechanical Engineering
Coronary Interventions and Diagnostics
2.01
article

Bending Flexibility of Negative Poisson's Ratio Structural Vascular Stent

Mohan Yang, Yao Du, Dongmei Zhu, Guoyong Liu, Xueqing Wu
article en
1 citations

Abstract

A negative Poisson's ratio structural vascular stent with arrow-shaped cell is proposed in the paper. In order to improve the bending flexibility of the stent, three shapes of connecting bars, namely, U-shaped, S-shaped, and linear, are designed. The influence of structural parameters of the stent connecting bars on the bending performance of the stent is studied using the finite element method and experimental method. The research results show that compared to S-shaped stents, U-shaped stents have better bending flexibility. In addition, the influence of the parameters of the connection bars of a U-shaped stent on its flexibility is also explored. The longer the length of the U-shaped connection bars, the lower the corresponding bending stiffness and better bending flexibility. The larger the width of the U-shaped connecting bar, the greater the bending stiffness of the stent, and the worse its bending flexibility. And some experiments are conducted using the four points bending method. The deformation of the S-shaped stent and U-shaped stent under bending is very similar, and the bending stiffness of the U-shaped stent is lower than that of the S-shaped bracket, which also verified the correctness of the finite element calculation.

Journal of Biomechanical EngineeringVol. 147(5)
University of Science and Technology Beijing (CN)
Good health and well-being
Openalex Percentile: Top 18%
Coronary Interventions and Diagnostics
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.