Design and performance of a compact field cage for the HERD side-on transition radiation detector

Abstract The ability of the side-on transition radiation detector (TRD) for High Energy Radiation Detector (HERD) to accurately calibrate energy of cosmic ray depends on the precision in measuring and identifying Transition Radiation (TR) photons. This requires maximizing the transmittance of TR photons to the sensitive volume and the collection of resulting electrons by the detector. An optimization of the field cage is necessary for both aspects. In response to the need for high TR photon transmittance from the side and a uniform electric field in a compact structure for the TRD, a dual-width strip structure field cage solution has been developed. This field cage has a TR photon transmittance of over 95%, 3D modeling based on the actual detector and Monte Carlo simulations indicate that the electron collection efficiency in the field cage can reach 97.2%. The test results for the energy response differences at various incident positions within the sensitive volume of the detector indicate that the normalized gain range is between 0.9 and 1.1, demonstrating good consistency.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-03-01
DOI
https://doi.org/10.1088/1748-0221/20/03/t03004
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and performance of a compact field cage for the HERD side-on transition radiation detector

Ping Wei, En‐Wei Liang, Cong Dai, Huanbo Feng et al.
Journal of Instrumentation
Particle Detector Development and Performance
article

Design and performance of a compact field cage for the HERD side-on transition radiation detector

Ping Wei, En‐Wei Liang, Cong Dai, Huanbo Feng, Jieyu Zhu, Huijun Hu, H. Liu, Yongwei Dong, Ruijie Wang, Xiwen Liu, Fan Jiang, Yan Yang
article en

Abstract

Abstract The ability of the side-on transition radiation detector (TRD) for High Energy Radiation Detector (HERD) to accurately calibrate energy of cosmic ray depends on the precision in measuring and identifying Transition Radiation (TR) photons. This requires maximizing the transmittance of TR photons to the sensitive volume and the collection of resulting electrons by the detector. An optimization of the field cage is necessary for both aspects. In response to the need for high TR photon transmittance from the side and a uniform electric field in a compact structure for the TRD, a dual-width strip structure field cage solution has been developed. This field cage has a TR photon transmittance of over 95%, 3D modeling based on the actual detector and Monte Carlo simulations indicate that the electron collection efficiency in the field cage can reach 97.2%. The test results for the energy response differences at various incident positions within the sensitive volume of the detector indicate that the normalized gain range is between 0.9 and 1.1, demonstrating good consistency.

Journal of InstrumentationVol. 20(03)
Guangxi University (CN), Chinese Academy of Sciences (CN), Institute of Modern Physics (CN), Institute of High Energy Physics (CN)
Openalex Percentile: Top 97%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.