An enzyme-free electrochemical glucose sensor based on ordered porous Co3O4 material

In this paper, Co3O4 was synthesized through a one-step conversion from the precursor of Co-MOF, which was prepared using the liquid phase method. It was subsequently employed to construct a novel electrochemical sensor for glucose detection. The ordered pores in the material not only provided numerous electrocatalytic active sites but also facilitated the diffusion and desorption of electrolyte ions, glucose molecules, and intermediate products, thereby enhancing the overall electrocatalytic activity. Co3O4 demonstrated favorable electrocatalytic performance towards glucose oxidation. The fabricated sensor exhibited a sensitivity of 617.4 μA/(mmol·cm2), with a detection limit as low as 0.23 μmol/L and a rapid response time within 5.9 seconds over a linear range from 0.62 μmol/L to 7.5 mmol/L. The sensor possesses several advantages including straightforward fabrication, satisfactory selectivity, and a low detection limit, thus broadening the application of metal-organic frameworks in the field of electrochemical sensing. KEY WORDS: Ordered porous material, Co3O4, Electrochemical sensor, Non-enzymatic glucose sensors Bull. Chem. Soc. Ethiop. 2025, 39(5), 807-815. DOI: https://dx.doi.org/10.4314/bcse.v39i5.1

Authors

Publication Details

Journal
Bulletin of the Chemical Society of Ethiopia
Published
2025-03-05
DOI
https://doi.org/10.4314/bcse.v39i5.1
Citations
3
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
2.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An enzyme-free electrochemical glucose sensor based on ordered porous Co3O4 material

Dunqing Wang, Jianzhi Sun, Xinfang Wang, Min Yang
3 citations
Bulletin of the Chemical Society of Ethiopia
Electrochemical sensors and biosensors
2.19
article

An enzyme-free electrochemical glucose sensor based on ordered porous Co3O4 material

Dunqing Wang, Jianzhi Sun, Xinfang Wang, Min Yang
article en
3 citations

Abstract

In this paper, Co3O4 was synthesized through a one-step conversion from the precursor of Co-MOF, which was prepared using the liquid phase method. It was subsequently employed to construct a novel electrochemical sensor for glucose detection. The ordered pores in the material not only provided numerous electrocatalytic active sites but also facilitated the diffusion and desorption of electrolyte ions, glucose molecules, and intermediate products, thereby enhancing the overall electrocatalytic activity. Co3O4 demonstrated favorable electrocatalytic performance towards glucose oxidation. The fabricated sensor exhibited a sensitivity of 617.4 μA/(mmol·cm2), with a detection limit as low as 0.23 μmol/L and a rapid response time within 5.9 seconds over a linear range from 0.62 μmol/L to 7.5 mmol/L. The sensor possesses several advantages including straightforward fabrication, satisfactory selectivity, and a low detection limit, thus broadening the application of metal-organic frameworks in the field of electrochemical sensing. KEY WORDS: Ordered porous material, Co3O4, Electrochemical sensor, Non-enzymatic glucose sensors Bull. Chem. Soc. Ethiop. 2025, 39(5), 807-815. DOI: https://dx.doi.org/10.4314/bcse.v39i5.1

Bulletin of the Chemical Society of EthiopiaVol. 39(5)
Openalex Percentile: Top 13%
Electrochemical sensors and biosensors
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.