Feasibility of tomographic freehand three-dimensional ultrasound for surveillance of abdominal aortic aneurysms after endovascular repair

ObjectivesThis study aimed to investigate the feasibility of a commercially available tomographic freehand three-dimensional ultrasound (3D-US) system for surveillance of abdominal aortic aneurysms (AAAs) after endovascular repair (EVAR).MethodsIn 10 patients who underwent EVAR, a 3D-US scan was obtained post-operatively in addition to regular computed tomography angiography (CTA). Five independent observers evaluated 12 EVAR surveillance parameters for the 10 scans, resulting in a total of 600 individual observations.ResultsThe diameters of the neck, sac and iliac arteries were evaluable in most of the observations (neck: 80%, AAA sac: 98%, right CIA: 90%, left CIA: 68%). The diameter measurements of the 3D-US strongly correlated with the diameters measured on CTA (<i>ρ</i> = 0.90, <i>p</i> < .001). The general offset of 3D-US compared to CTA was -4.4 mm and the proportional bias was 3%. For all observers, the diameter measurements were significantly strongly correlated (O1:ρ = 0.85, O2:ρ = 0.88, O3:ρ = 0.93, O4:ρ = 0.96, O5:ρ = 0.86, <i>p</i> < .001 for all). The inter-observer reliability was excellent with an overall concordance correlation coefficient of 0.98. The start of the endograft, the lowest renal artery, the distance between these landmarks, and the proximal and distal sealing zones were evaluable in fewer than half of the observations (42%, 12%, 10%, 32%, 32%, 26%).Conclusion3D-US after EVAR is feasible. Diameters measured in 3D-US correlate strongly with CTA-based diameters and have a good interrater variability. However, the sealing zones are difficult to assess on 3D-US. This technique could be a useful addition to duplex ultrasound to facilitate offline 3D analysis, increase measurement reproducibility, enable volume measurements, and minimise the use of harmful CTA for surveillance after EVAR.

Authors

Institutions

Publication Details

Journal
Vascular
Published
2025-03-13
DOI
https://doi.org/10.1177/17085381251327171
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of tomographic freehand three-dimensional ultrasound for surveillance of abdominal aortic aneurysms after endovascular repair

Jelmer M. Wolterink, Michel M.P.J. Reijnen, Erik Groot Jebbink, R E van Rijswijk et al.
Vascular
Aortic aneurysm repair treatments
article

Feasibility of tomographic freehand three-dimensional ultrasound for surveillance of abdominal aortic aneurysms after endovascular repair

Jelmer M. Wolterink, Michel M.P.J. Reijnen, Erik Groot Jebbink, R E van Rijswijk, Suzan R.T. Everink
article en

Abstract

ObjectivesThis study aimed to investigate the feasibility of a commercially available tomographic freehand three-dimensional ultrasound (3D-US) system for surveillance of abdominal aortic aneurysms (AAAs) after endovascular repair (EVAR).MethodsIn 10 patients who underwent EVAR, a 3D-US scan was obtained post-operatively in addition to regular computed tomography angiography (CTA). Five independent observers evaluated 12 EVAR surveillance parameters for the 10 scans, resulting in a total of 600 individual observations.ResultsThe diameters of the neck, sac and iliac arteries were evaluable in most of the observations (neck: 80%, AAA sac: 98%, right CIA: 90%, left CIA: 68%). The diameter measurements of the 3D-US strongly correlated with the diameters measured on CTA (<i>ρ</i> = 0.90, <i>p</i> < .001). The general offset of 3D-US compared to CTA was -4.4 mm and the proportional bias was 3%. For all observers, the diameter measurements were significantly strongly correlated (O1:ρ = 0.85, O2:ρ = 0.88, O3:ρ = 0.93, O4:ρ = 0.96, O5:ρ = 0.86, <i>p</i> < .001 for all). The inter-observer reliability was excellent with an overall concordance correlation coefficient of 0.98. The start of the endograft, the lowest renal artery, the distance between these landmarks, and the proximal and distal sealing zones were evaluable in fewer than half of the observations (42%, 12%, 10%, 32%, 32%, 26%).Conclusion3D-US after EVAR is feasible. Diameters measured in 3D-US correlate strongly with CTA-based diameters and have a good interrater variability. However, the sealing zones are difficult to assess on 3D-US. This technique could be a useful addition to duplex ultrasound to facilitate offline 3D analysis, increase measurement reproducibility, enable volume measurements, and minimise the use of harmful CTA for surveillance after EVAR.

VascularVol. 34(1)
Rijnstate Hospital (NL), University of Twente (NL)
Stichting Lijf en Leven
Good health and well-being
Openalex Percentile: Top 93%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.