Investigating the Effects of Occupancy and Natural Ventilation on the Indoor Air Quality of Dormitories in Cold Regions

Indoor air quality (IAQ) in higher education institutions’ dormitories, without mechanical ventilation, is a significant concern for students’ health due to prolonged occupancy in cold regions. The present investigation assessed IAQ by measuring two dormitories’ CO2, temperature, and relative humidity with the presence of one, two, three, and four occupants in the United Kingdom. Considering the possibility of natural ventilation by opening the windows in the summer, IAQ was monitored using two sensors located at 1 m and 2 m heights from the floor level of the dormitories in July. The tracer mass balance model showed close agreement with the monitored IAQ levels, with a direct relationship observed between occupant numbers and CO2 build-up. CO2 levels exceeded 1000 ppm within an hour during occupancy and closed ventilation, with air exchange rates between 0.12 and 0.2 h−1, increasing to 1334, 1259, 1884, and 2064 ppm after 30 min with one, two, three, and four occupants, respectively. Desired IAQ standards (1000 ppm) were achieved in 13, 33, 80, and 86 min for one, two, three, and four occupants after starting natural ventilation by opening 20% of the windows. The analysis of variance affirmed the effect of occupancy on IAQ, while the impact of height (1 m and 2 m) on CO2 levels was insignificant. This study underscores the need to effectively ventilate the partial opening of windows in dormitories to mitigate CO2 build-up, ensuring the desired ambient environment within dormitory rooms during summers in cold regions.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-03-13
DOI
https://doi.org/10.3390/buildings15060896
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating the Effects of Occupancy and Natural Ventilation on the Indoor Air Quality of Dormitories in Cold Regions

Husnain Haider, Majed Alinizzi, Abdul Razzaq Ghumman, Md. Shafiquzzaman et al.
1 citations
Buildings
Building Energy and Comfort Optimization
1.01
article

Investigating the Effects of Occupancy and Natural Ventilation on the Indoor Air Quality of Dormitories in Cold Regions

Husnain Haider, Majed Alinizzi, Abdul Razzaq Ghumman, Md. Shafiquzzaman, Guangji Hu, Irfan M Nasir
article en
1 citations

Abstract

Indoor air quality (IAQ) in higher education institutions’ dormitories, without mechanical ventilation, is a significant concern for students’ health due to prolonged occupancy in cold regions. The present investigation assessed IAQ by measuring two dormitories’ CO2, temperature, and relative humidity with the presence of one, two, three, and four occupants in the United Kingdom. Considering the possibility of natural ventilation by opening the windows in the summer, IAQ was monitored using two sensors located at 1 m and 2 m heights from the floor level of the dormitories in July. The tracer mass balance model showed close agreement with the monitored IAQ levels, with a direct relationship observed between occupant numbers and CO2 build-up. CO2 levels exceeded 1000 ppm within an hour during occupancy and closed ventilation, with air exchange rates between 0.12 and 0.2 h−1, increasing to 1334, 1259, 1884, and 2064 ppm after 30 min with one, two, three, and four occupants, respectively. Desired IAQ standards (1000 ppm) were achieved in 13, 33, 80, and 86 min for one, two, three, and four occupants after starting natural ventilation by opening 20% of the windows. The analysis of variance affirmed the effect of occupancy on IAQ, while the impact of height (1 m and 2 m) on CO2 levels was insignificant. This study underscores the need to effectively ventilate the partial opening of windows in dormitories to mitigate CO2 build-up, ensuring the desired ambient environment within dormitory rooms during summers in cold regions.

BuildingsVol. 15(6)
Qingdao University (CN), Qassim University (SA), University of Birmingham (GB)
Openalex Percentile: Top 27%
Building Energy and Comfort Optimization
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.