Single crystal linear array for modal decomposition analysis

Abstract. The characterisation of a 16-element acoustic emission (AE) sensor manufactured using relaxor ferroelectric single crystal (RFSC) is reported. The sensor, a linear array for modal decomposition and analysis (LAMDA) based on piezoelectric transduction, can be used for AE-based damage detection in aerospace, land, and sea applications. The RFSC LAMDA sensor was mounted on a 1.6 mm thick aluminium plate, the response of the sensor to AE excitations produced via pencil lead break (PLB) was examined. PLB break-energy generated by various pencil lead-types were examined experimentally. HB pencil lead 3 mm long, 0.5 mm diameter, has a measured break-energy of 6.6 µJ. Experimentally, RFSC LAMDA was able to detect the 6.6 µJ PLB excitation at a distance of 200 mm across the 1.6 mm aluminium plate. Modal decomposition of modelled and measured signals produced by the RFSC LAMDA in response to A0 and S0 Lamb waves, in a 1.6 mm aluminium plate, are compared and found to be in good agreement.

Authors

Institutions

Publication Details

Journal
Materials research proceedings
Published
2025-03-13
DOI
https://doi.org/10.21741/9781644903513-27
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single crystal linear array for modal decomposition analysis

Eliza Baddiley
Materials research proceedings
Structural Health Monitoring Techniques
article

Single crystal linear array for modal decomposition analysis

Eliza Baddiley
article en

Abstract

Abstract. The characterisation of a 16-element acoustic emission (AE) sensor manufactured using relaxor ferroelectric single crystal (RFSC) is reported. The sensor, a linear array for modal decomposition and analysis (LAMDA) based on piezoelectric transduction, can be used for AE-based damage detection in aerospace, land, and sea applications. The RFSC LAMDA sensor was mounted on a 1.6 mm thick aluminium plate, the response of the sensor to AE excitations produced via pencil lead break (PLB) was examined. PLB break-energy generated by various pencil lead-types were examined experimentally. HB pencil lead 3 mm long, 0.5 mm diameter, has a measured break-energy of 6.6 µJ. Experimentally, RFSC LAMDA was able to detect the 6.6 µJ PLB excitation at a distance of 200 mm across the 1.6 mm aluminium plate. Modal decomposition of modelled and measured signals produced by the RFSC LAMDA in response to A0 and S0 Lamb waves, in a 1.6 mm aluminium plate, are compared and found to be in good agreement.

Materials research proceedingsVol. 50
Defence Science and Technology Group (AU)
DMTC, Defence Science and Technology Group
Openalex Percentile: Top 95%
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.