Reviewing the fundamentals and best practices to characterize microplastics using state–of–the-art quantum-cascade laser reflectance-absorbance spectroscopy

Microplastic pollution studies depend on reliable identification of the suspicious particles. Out of the various analytical techniques available to characterize them, infrared transflectance using a tuneable mid-IR quantum cascade laser is a high-throughput state-of-the-art imaging option, specifically Agilent's QCL-LDIR (Quantum Cascade Laser Direct Infrared imaging). Its conceptual grounds are reviewed, instrumental developments are discussed, along with a review of applications and best practices to overcome obstacles/difficulties in routine measurements, namely: the spectral range, the variation of some peak intensities with the particles size, processing speed, and avoiding the use of measurement aliquots. Objective procedures to avoid too many false positives when identifying spectra and to distinguish fibers and fragments are given. These practices open a path to QCL-LDIR measurement standardization and potential use for microplastics monitoring, as requested by many governmental bodies in charge of setting environmental protection rules. • It is shown that the experimental setup can alter the final identification of suspicious particles. • Reducing number of particles and measurement area per project accelerate measurements. • Due to transflectance phenomena, measured spectra depend nonlinearly on the particle size. • A way to evaluate the length penetration of the laser beam is proposed for some polymers. • Three levels of reliability are proposed to report match of unknowns to spectral databases.

Authors

Institutions

Publication Details

Journal
TrAC Trends in Analytical Chemistry
Published
2025-03-13
DOI
https://doi.org/10.1016/j.trac.2025.118229
Citations
6
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
3.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reviewing the fundamentals and best practices to characterize microplastics using state–of–the-art quantum-cascade laser reflectance-absorbance spectroscopy

Adrián López-Rosales, Soledad Muniategui‐Lorenzo, Borja Ferreiro, J.M. Andrade et al.
6 citations
TrAC Trends in Analytical Chemistry
Microplastics and Plastic Pollution
3.02
article

Reviewing the fundamentals and best practices to characterize microplastics using state–of–the-art quantum-cascade laser reflectance-absorbance spectroscopy

Adrián López-Rosales, Soledad Muniategui‐Lorenzo, Borja Ferreiro, J.M. Andrade, Andreas Kerstan, Darren Robey
article en
6 citations

Abstract

Microplastic pollution studies depend on reliable identification of the suspicious particles. Out of the various analytical techniques available to characterize them, infrared transflectance using a tuneable mid-IR quantum cascade laser is a high-throughput state-of-the-art imaging option, specifically Agilent's QCL-LDIR (Quantum Cascade Laser Direct Infrared imaging). Its conceptual grounds are reviewed, instrumental developments are discussed, along with a review of applications and best practices to overcome obstacles/difficulties in routine measurements, namely: the spectral range, the variation of some peak intensities with the particles size, processing speed, and avoiding the use of measurement aliquots. Objective procedures to avoid too many false positives when identifying spectra and to distinguish fibers and fragments are given. These practices open a path to QCL-LDIR measurement standardization and potential use for microplastics monitoring, as requested by many governmental bodies in charge of setting environmental protection rules. • It is shown that the experimental setup can alter the final identification of suspicious particles. • Reducing number of particles and measurement area per project accelerate measurements. • Due to transflectance phenomena, measured spectra depend nonlinearly on the particle size. • A way to evaluate the length penetration of the laser beam is proposed for some polymers. • Three levels of reliability are proposed to report match of unknowns to spectral databases.

TrAC Trends in Analytical ChemistryVol. 188
Universidade da Coruña (ES), Hewlett-Packard (Italy) (IT), Agilent Technologies (Australia) (AU)
Openalex Percentile: Top 9%
Microplastics and Plastic Pollution
3.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.