High-Performance Metal Ion Coordination Polymer Humidity Sensor with High Sensitivity, Real-Time Monitoring, and Wide Range Measurements

As the demand for environmental monitoring and industrial applications increases, the significance of humidity sensors in various fields has grown substantially. However, traditional humidity sensors are hindered by slow response times, substantial hysteresis, and inadequate stability, which limit their applicability in high-precision environments. To overcome these limitations, this study introduces an ion-capacitive humidity sensor based on poly(vinyl alcohol)-magnesium (PVA-Mg(II)). The sensor is fabricated using a straightforward solution-based method, and it leverages ion migration as the primary response mechanism, thereby significantly enhancing humidity response sensitivity compared to conventional electronic sensors. The PVA-Mg(II) sensor achieves a humidity response of up to 1420% within the 36% to 97% RH range, with a broad detection range spanning from 2% to 97% RH. The sensor exhibits response and recovery times of 15 and 2 s, respectively, with minimal hysteresis. Furthermore, the sensor demonstrates exceptional long-term stability, maintaining consistent performance for over 100 h within the 2% to 61% RH range, underscoring its superior humidity detection capabilities. By improving humidity response sensitivity through ion migration and exhibiting low hysteresis, the sensor effectively addresses the inherent limitations of traditional humidity sensors in terms of stability and response speed, offering significant potential for a wide range of practical applications.

Authors

Institutions

Publication Details

Journal
ACS Applied Electronic Materials
Published
2025-03-13
DOI
https://doi.org/10.1021/acsaelm.5c00015
Citations
1
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Performance Metal Ion Coordination Polymer Humidity Sensor with High Sensitivity, Real-Time Monitoring, and Wide Range Measurements

Jincan Cui, Xiaolei Yuan, Jia Dong Huang, Li Li et al.
1 citations
ACS Applied Electronic Materials
Gas Sensing Nanomaterials and Sensors
0.73
article

High-Performance Metal Ion Coordination Polymer Humidity Sensor with High Sensitivity, Real-Time Monitoring, and Wide Range Measurements

Jincan Cui, Xiaolei Yuan, Jia Dong Huang, Li Li, Shiqi Zhang, Heng Wang, Cheng Qu, Ziyi Guo, C.Y. Wei
article en
1 citations

Abstract

As the demand for environmental monitoring and industrial applications increases, the significance of humidity sensors in various fields has grown substantially. However, traditional humidity sensors are hindered by slow response times, substantial hysteresis, and inadequate stability, which limit their applicability in high-precision environments. To overcome these limitations, this study introduces an ion-capacitive humidity sensor based on poly(vinyl alcohol)-magnesium (PVA-Mg(II)). The sensor is fabricated using a straightforward solution-based method, and it leverages ion migration as the primary response mechanism, thereby significantly enhancing humidity response sensitivity compared to conventional electronic sensors. The PVA-Mg(II) sensor achieves a humidity response of up to 1420% within the 36% to 97% RH range, with a broad detection range spanning from 2% to 97% RH. The sensor exhibits response and recovery times of 15 and 2 s, respectively, with minimal hysteresis. Furthermore, the sensor demonstrates exceptional long-term stability, maintaining consistent performance for over 100 h within the 2% to 61% RH range, underscoring its superior humidity detection capabilities. By improving humidity response sensitivity through ion migration and exhibiting low hysteresis, the sensor effectively addresses the inherent limitations of traditional humidity sensors in terms of stability and response speed, offering significant potential for a wide range of practical applications.

ACS Applied Electronic MaterialsVol. 7(6)
Tongji University (CN), Nantong University (CN), Nanjing Drum Tower Hospital (CN), Nanjing University (CN)
Natural Science Foundation of Nantong City, National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality, Graduate Research and Innovation Projects of Jiangsu Province, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 31%
Gas Sensing Nanomaterials and Sensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.