Reliability of Shear Wave Elastography for Measuring the Elastic Properties of the Quadratus Lumborum Muscle

<b>Background/Objectives</b>: The quadratus lumborum (QL) muscle is a key structure involved in patients with low back pain (LBP). Since the discriminative capability of morphological descriptors is uncertain and considering the high prevalence of myofascial trigger points and the poor reliability of manual palpation in this condition, developing a reliable procedure for assessing the QL's tenderness is needed for facilitating the diagnosis and monitoring changes over time. We aimed to analyze the intra- and inter-examiner reliability of SWE for calculating the QL tenderness in patients with LBP. <b>Methods</b>: Using a convex transducer, longitudinal shear wave elastography (SWE) images of the QL muscle were acquired bilaterally twice in 52 volunteers with moderate LBP and disability by one experienced examiner and one novel examiner to measure shear wave speed and Young's modulus as stiffness metrics. <b>Results</b>: Intra-examiner reliability estimates demonstrated high consistency independently of the examiner's experience (intraclass correlation coefficients (ICCs) > 0.930) for both metrics. However, experienced examiners showed smaller minimal detectable changes. Additionally, inter-examiner reliability was lower, with ICCs ranging from 0.57 to 0.68, and significant differences in mean values between examiners (<i>p</i> < 0.01) were found. <b>Conclusions</b>: This procedure exhibited excellent intra-examiner reliability for assessing QL muscle stiffness in patients suffering LBP, indicating high repeatability of measurements when performed by the same examiner. In addition, experienced examiners demonstrated greater sensitivity in detecting real changes not attributed to measurement errors. However, inter-examiner reliability was moderate, highlighting the need for consistent examiner use to avoid measurement variability and averaging multiple measurements to enhance the accuracy.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-03-13
DOI
https://doi.org/10.3390/diagnostics15060722
Citations
1
Primary Topic
Musculoskeletal pain and rehabilitation
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of Shear Wave Elastography for Measuring the Elastic Properties of the Quadratus Lumborum Muscle

Alberto Roldán‐Ruiz, Juan Antonio Valera‐Calero, Sandra Sánchez-Jorge, Jorge Buffet‐García et al.
1 citations
Diagnostics
Musculoskeletal pain and rehabilitation
1.39
article

Reliability of Shear Wave Elastography for Measuring the Elastic Properties of the Quadratus Lumborum Muscle

Alberto Roldán‐Ruiz, Juan Antonio Valera‐Calero, Sandra Sánchez-Jorge, Jorge Buffet‐García, Davinia Vicente-Campos, Javier Álvarez-González, Mónica López-Redondo, Germán Monclús-Díez
article en
1 citations

Abstract

<b>Background/Objectives</b>: The quadratus lumborum (QL) muscle is a key structure involved in patients with low back pain (LBP). Since the discriminative capability of morphological descriptors is uncertain and considering the high prevalence of myofascial trigger points and the poor reliability of manual palpation in this condition, developing a reliable procedure for assessing the QL's tenderness is needed for facilitating the diagnosis and monitoring changes over time. We aimed to analyze the intra- and inter-examiner reliability of SWE for calculating the QL tenderness in patients with LBP. <b>Methods</b>: Using a convex transducer, longitudinal shear wave elastography (SWE) images of the QL muscle were acquired bilaterally twice in 52 volunteers with moderate LBP and disability by one experienced examiner and one novel examiner to measure shear wave speed and Young's modulus as stiffness metrics. <b>Results</b>: Intra-examiner reliability estimates demonstrated high consistency independently of the examiner's experience (intraclass correlation coefficients (ICCs) > 0.930) for both metrics. However, experienced examiners showed smaller minimal detectable changes. Additionally, inter-examiner reliability was lower, with ICCs ranging from 0.57 to 0.68, and significant differences in mean values between examiners (<i>p</i> < 0.01) were found. <b>Conclusions</b>: This procedure exhibited excellent intra-examiner reliability for assessing QL muscle stiffness in patients suffering LBP, indicating high repeatability of measurements when performed by the same examiner. In addition, experienced examiners demonstrated greater sensitivity in detecting real changes not attributed to measurement errors. However, inter-examiner reliability was moderate, highlighting the need for consistent examiner use to avoid measurement variability and averaging multiple measurements to enhance the accuracy.

DiagnosticsVol. 15(6)
Universidad Complutense de Madrid (ES), Universidad Francisco de Vitoria (ES), Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (ES)
Reduced inequalities
Openalex Percentile: Top 23%
Musculoskeletal pain and rehabilitation
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.