Micro-Pointed Electrode Optimization for Platelet-RBC Separation via Dielectrophoresis: A Computational Approach with COMSOL and Fuzzy Logic

This abstract highlights the optimization of micro-pointed chip design through COMSOL Multiphysics modeling and MATLAB-Fuzzy Logic analysis to enhance platelet-RBC separation. The results emphasize the importance of fine-tuning operational parameters and showcase the potential of microfluidic systems for various medical applications. To separate the platelets from the RBCs, we used a different size-based micro-pointed electrode model and found that the blood's input velocity should be between 600 and 1000 μm/s, and the appropriate voltage to apply to the microfluidic chip should be between 4 and 7 V. When these input values are applied for a microchannel length of 720 μm, the microfluidic exit channel is subject to a maximum pressure of 5.8-6 Pa and a maximum velocity of 1.3-1.5 mm/s. These findings demonstrate the ideal circumstances needed to separate platelets from red blood cells.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/wiecon-ece64149.2024.10915107
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Micro-Pointed Electrode Optimization for Platelet-RBC Separation via Dielectrophoresis: A Computational Approach with COMSOL and Fuzzy Logic

Nasrin Akhter, Most. Jaytun Nahar
Microfluidic and Capillary Electrophoresis Applications
article

Micro-Pointed Electrode Optimization for Platelet-RBC Separation via Dielectrophoresis: A Computational Approach with COMSOL and Fuzzy Logic

Nasrin Akhter, Most. Jaytun Nahar
article en

Abstract

This abstract highlights the optimization of micro-pointed chip design through COMSOL Multiphysics modeling and MATLAB-Fuzzy Logic analysis to enhance platelet-RBC separation. The results emphasize the importance of fine-tuning operational parameters and showcase the potential of microfluidic systems for various medical applications. To separate the platelets from the RBCs, we used a different size-based micro-pointed electrode model and found that the blood's input velocity should be between 600 and 1000 μm/s, and the appropriate voltage to apply to the microfluidic chip should be between 4 and 7 V. When these input values are applied for a microchannel length of 720 μm, the microfluidic exit channel is subject to a maximum pressure of 5.8-6 Pa and a maximum velocity of 1.3-1.5 mm/s. These findings demonstrate the ideal circumstances needed to separate platelets from red blood cells.

Khulna University of Engineering and Technology (BD), Khulna Medical College (BD), Sheikh Hasina Medical University
Openalex Percentile: Top 75%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.