An Imaging System to Support Fast Neutron Therapy Quality Assurance (QA) of Intensity Modulated Neutron Therapy (IMNT)

The University of Washington Medical Center has clinically implemented intensity modulated neutron therapy (IMNT) as a novel, high linear energy transfer modality for palliative and curative treatments of certain cancers. Because of the destructive nature of fast neutrons to electronics, this required development of a novel patient specific quality assurance (QA) system. Therefore, we developed an in-house 2-D positron emission tomography (PET) system that images patient-specific QA fields by measuring induced 11C positron activity in polyethylene plates. The scanner is built around two parallel imaging panels of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2\times 16$ </tex-math></inline-formula> repurposed clinical PET detector modules. Images are reconstructed using focal plane tomography in a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$14\times 16$ </tex-math></inline-formula> cm2 field of view. Standard metrics (gamma analysis) are used to compare images with simulated (MCNP6) fluence maps. Studies demonstrated a linear dose-response relationship and full system [x, y] spatial resolution of [<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5.2~\pm ~0.30$ </tex-math></inline-formula>, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5.3~\pm ~0.34$ </tex-math></inline-formula>] mm2 with 1 mm-diameter point source. Final image spatial resolution is approximately 8.5 mm FWHM due to the geometry of the polyethylene plates. Energy resolution (FWHM) in the center crystals is <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$28~\pm ~3$ </tex-math></inline-formula>%. Assembly, characterization, and quantitative calibration of the neutron Positron Emission Portal Imaging (nPEPI) system was completed in 2022, and more than 100 patients have since completed QA.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2025-03-13
DOI
https://doi.org/10.1109/trpms.2025.3551208
Citations
1
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Imaging System to Support Fast Neutron Therapy Quality Assurance (QA) of Intensity Modulated Neutron Therapy (IMNT)

David C. Argento, M. Kranz, Adrienne L. Lehnert, Robert S. Miyaoka et al.
1 citations
IEEE Transactions on Radiation and Plasma Medical Sciences
Nuclear Physics and Applications
1.88
article

An Imaging System to Support Fast Neutron Therapy Quality Assurance (QA) of Intensity Modulated Neutron Therapy (IMNT)

David C. Argento, M. Kranz, Adrienne L. Lehnert, Robert S. Miyaoka, Dawn E. DeWitt, Robert D. Stewart
article en
1 citations

Abstract

The University of Washington Medical Center has clinically implemented intensity modulated neutron therapy (IMNT) as a novel, high linear energy transfer modality for palliative and curative treatments of certain cancers. Because of the destructive nature of fast neutrons to electronics, this required development of a novel patient specific quality assurance (QA) system. Therefore, we developed an in-house 2-D positron emission tomography (PET) system that images patient-specific QA fields by measuring induced 11C positron activity in polyethylene plates. The scanner is built around two parallel imaging panels of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2\times 16$ </tex-math></inline-formula> repurposed clinical PET detector modules. Images are reconstructed using focal plane tomography in a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$14\times 16$ </tex-math></inline-formula> cm2 field of view. Standard metrics (gamma analysis) are used to compare images with simulated (MCNP6) fluence maps. Studies demonstrated a linear dose-response relationship and full system [x, y] spatial resolution of [<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5.2~\pm ~0.30$ </tex-math></inline-formula>, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5.3~\pm ~0.34$ </tex-math></inline-formula>] mm2 with 1 mm-diameter point source. Final image spatial resolution is approximately 8.5 mm FWHM due to the geometry of the polyethylene plates. Energy resolution (FWHM) in the center crystals is <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$28~\pm ~3$ </tex-math></inline-formula>%. Assembly, characterization, and quantitative calibration of the neutron Positron Emission Portal Imaging (nPEPI) system was completed in 2022, and more than 100 patients have since completed QA.

IEEE Transactions on Radiation and Plasma Medical SciencesVol. 9(7)
University of Washington (US)
Openalex Percentile: Top 20%
Nuclear Physics and Applications
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.