Exergy analysis of the effects of extreme hot conditions on cooling system efficiency: A case study of a split air conditioner

The performance of thermal systems is directly affected by the surrounding external conditions, especially those characterized by a hot climate and low relative humidity in the summer . It may enhance thermal system inefficiencies during peak daytime hours. The present work aims to study the thermal and exergonic performance of a 4-ton split air conditioning system operating under extremely hot and dry climatic conditions, such as those found in Baghdad, Iraq. The components of the air conditioner charged with 5.5 kg of R-22 refrigerant were tested at room temperature (23 °C) and in ambient temperatures (30 °C to 60 °C). Data were collected from 7:00 am to 3:00 pm in July using temperature sensors, pressure transmitters and humidity sensors. The study found that the system pressure ratio increased when the outdoor temperature rose from 30 to 60 °C, which in turn increased the energy consumption of the compressor and decreased the cooling effect of the evaporator. The compressor's volumetric and isentropic efficiencies dropped due to rising ambient temperatures. The rise in ambient temperature raised power consumption, which subsequently resulted in a reduction in the Carnot efficiency and the system's coefficient of performance (COP). The highest exergy destruction (ED) occurred in the compressor at higher ambient temperatures, while the minimum ED occurred in the expansion valve. The rising ambient temperature enhances system entropy generation and ED, resulting in reduced exergy efficiency (EE) of the air conditioner.

Authors

Institutions

Publication Details

Journal
Case Studies in Chemical and Environmental Engineering
Published
2025-03-12
DOI
https://doi.org/10.1016/j.cscee.2025.101187
Citations
6
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
4.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exergy analysis of the effects of extreme hot conditions on cooling system efficiency: A case study of a split air conditioner

Jalal Faraj, Ahmed Mohsin Alsayah, Mohammed J. Alshukri, Mahmoud Khaled et al.
6 citations
Case Studies in Chemical and Environmental Engineering
Refrigeration and Air Conditioning Technologies
4.28
article

Exergy analysis of the effects of extreme hot conditions on cooling system efficiency: A case study of a split air conditioner

Jalal Faraj, Ahmed Mohsin Alsayah, Mohammed J. Alshukri, Mahmoud Khaled, Adel A. Eidan, Samer Ali, Ibrahim S. Resen
article en
6 citations

Abstract

The performance of thermal systems is directly affected by the surrounding external conditions, especially those characterized by a hot climate and low relative humidity in the summer . It may enhance thermal system inefficiencies during peak daytime hours. The present work aims to study the thermal and exergonic performance of a 4-ton split air conditioning system operating under extremely hot and dry climatic conditions, such as those found in Baghdad, Iraq. The components of the air conditioner charged with 5.5 kg of R-22 refrigerant were tested at room temperature (23 °C) and in ambient temperatures (30 °C to 60 °C). Data were collected from 7:00 am to 3:00 pm in July using temperature sensors, pressure transmitters and humidity sensors. The study found that the system pressure ratio increased when the outdoor temperature rose from 30 to 60 °C, which in turn increased the energy consumption of the compressor and decreased the cooling effect of the evaporator. The compressor's volumetric and isentropic efficiencies dropped due to rising ambient temperatures. The rise in ambient temperature raised power consumption, which subsequently resulted in a reduction in the Carnot efficiency and the system's coefficient of performance (COP). The highest exergy destruction (ED) occurred in the compressor at higher ambient temperatures, while the minimum ED occurred in the expansion valve. The rising ambient temperature enhances system entropy generation and ED, resulting in reduced exergy efficiency (EE) of the air conditioner.

Case Studies in Chemical and Environmental EngineeringVol. 11
Ministry of Science and Technology (BA), Gulf University for Science & Technology (KW), Institut Mines-Télécom (FR), Université de Lille (FR), Iraqi University (IQ), International University of Beirut (LB), Al-Furat Al-Awsat Technical University (IQ), Laboratoire de Génie Civil et Géo Environnement (FR), Université d'Artois (FR), University of Kufa (IQ), Lebanese International University (LB)
Affordable and clean energy
Openalex Percentile: Top 6%
Refrigeration and Air Conditioning Technologies
4.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.