Active Disturbance Rejection-Based Model Predictive Control to Improve Power Quality with Reduced Current Sensors in EV Charging Stations

This paper proposes an active disturbance rejection (ADR)-based model predictive control (MPC) strategy to enhance power quality in electric vehicle charging stations (EVCS) with a reduced number of current sensors. The presented approach compensates for local load current harmonics and reactive power without the need for harmonic extraction, simplifying the control structure. By relying on current measurements only at the grid side, the method eliminates the need for additional sensors in the load or converter of the EVCS. Load current dynamics are considered as disturbance terms, then are rejected using the ADR technique. The proposed converter system simultaneously improves the grid’s power quality and fulfills its primary function of charging EVs. Simulation results validate the effectiveness of the approach, demonstrating enhanced power quality performance and robust disturbance rejection.

Authors

Institutions

Publication Details

Published
2025-02-04
DOI
https://doi.org/10.1109/pedstc65486.2025.10912064
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Active Disturbance Rejection-Based Model Predictive Control to Improve Power Quality with Reduced Current Sensors in EV Charging Stations

S. Alireza Davari, José Rodríguez, Behnam Nikmaram, Mokhtar Aly et al.
Advanced Battery Technologies Research
article

Active Disturbance Rejection-Based Model Predictive Control to Improve Power Quality with Reduced Current Sensors in EV Charging Stations

S. Alireza Davari, José Rodríguez, Behnam Nikmaram, Mokhtar Aly, Freddy Flores‐Bahamonde, Mahdi S. Mousavi, Mohammad Bagher Rahmani
article en

Abstract

This paper proposes an active disturbance rejection (ADR)-based model predictive control (MPC) strategy to enhance power quality in electric vehicle charging stations (EVCS) with a reduced number of current sensors. The presented approach compensates for local load current harmonics and reactive power without the need for harmonic extraction, simplifying the control structure. By relying on current measurements only at the grid side, the method eliminates the need for additional sensors in the load or converter of the EVCS. Load current dynamics are considered as disturbance terms, then are rejected using the ADR technique. The proposed converter system simultaneously improves the grid’s power quality and fulfills its primary function of charging EVs. Simulation results validate the effectiveness of the approach, demonstrating enhanced power quality performance and robust disturbance rejection.

Universidad Andrés Bello (CL), San Sebastián University (CL), Shahid Rajaee Teacher Training University (IR)
Affordable and clean energy
Openalex Percentile: Top 96%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.