Diagnosing of High Voltage Power Supplies of Ion Pumps through Low Current Measurements

High voltage power supplies of ion pumps are widely used in numerous applications requiring ultra-high vacuum conditions. However, when they operate at very low pressures, determining their proper functioning becomes challenging. In this paper, a current measurement circuit is suggested, which includes two amplifiers and is well-suited for ion pump high-voltage power supplies. However, error-causing parameters in both amplifiers and resistors lead to inaccuracies in current measurement. Consequently, there is a limitation on the minimum measurable current, with its extent depending on the specifications of the circuit elements and the desired measurement accuracy. To evaluate the method’s feasibility, the proposed current measurement circuit undergoes modeling and analysis to quantify inaccuracies resulting from error-causing parameters in the current measurement. Subsequently, the minimum measurable current with the desired measurement accuracy using specific conventional amplifiers in the suggested circuit is calculated and experimentally validated under various conditions.

Authors

Institutions

Publication Details

Published
2025-02-04
DOI
https://doi.org/10.1109/pedstc65486.2025.10912054
Citations
1
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.68
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnosing of High Voltage Power Supplies of Ion Pumps through Low Current Measurements

Shahriyar Kaboli, Amir Habibi, Sadra Kateb
1 citations
Advanced Battery Technologies Research
0.68
article

Diagnosing of High Voltage Power Supplies of Ion Pumps through Low Current Measurements

Shahriyar Kaboli, Amir Habibi, Sadra Kateb
article en
1 citations

Abstract

High voltage power supplies of ion pumps are widely used in numerous applications requiring ultra-high vacuum conditions. However, when they operate at very low pressures, determining their proper functioning becomes challenging. In this paper, a current measurement circuit is suggested, which includes two amplifiers and is well-suited for ion pump high-voltage power supplies. However, error-causing parameters in both amplifiers and resistors lead to inaccuracies in current measurement. Consequently, there is a limitation on the minimum measurable current, with its extent depending on the specifications of the circuit elements and the desired measurement accuracy. To evaluate the method’s feasibility, the proposed current measurement circuit undergoes modeling and analysis to quantify inaccuracies resulting from error-causing parameters in the current measurement. Subsequently, the minimum measurable current with the desired measurement accuracy using specific conventional amplifiers in the suggested circuit is calculated and experimentally validated under various conditions.

Sharif University of Technology (IR)
Affordable and clean energy
Openalex Percentile: Top 33%
Advanced Battery Technologies Research
0.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Diagnosing of High Voltage Power Supplies of Ion Pumps through Low Current Measurements — Shahriyar Kaboli, Amir Habibi, et al. · (2025) | TGRS Research Map | TGRS