Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair

Minimally invasive mitral valve repair offers significant advantages over traditional open-heart surgery, yet it remains a complex procedure that exposes both patients and medical staff to radiation. To address these challenges, a significant research interest is growing in automating these manual procedures. Continuum robots represent a promising approach, thanks to their ability to navigate confined spaces. However, their nonlinear behavior presents challenges in modeling and control. In this study, we developed a robust position control method for a variable-length tendon-driven continuum robot. We designed a control system that effectively tracks the desired target positions by employing a constant curvature model and a Jacobian-based control algorithm with real-time position feedback. We assessed the stability of our system through Lyapunov analysis, demonstrating reliable convergence to these target positions. Experimental validation conducted in a cardiovascular phantom demonstrated significant improvements with respect to the state of the art. Our method achieved a trajectory following error of approximately 2.43 mm [1.63, 3.23] and a target position error of about 1.92 mm [1.73, 3.13]. Moreover, the computation time per trajectory point was reduced to approximately 0.04 seconds, highlighting enhanced computational efficiency. These results showcase improved accuracy and efficiency in minimally invasive mitral valve repair procedures.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Robotics and Bionics
Published
2025-03-12
DOI
https://doi.org/10.1109/tmrb.2025.3550674
Citations
2
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
2.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair

Angela Peloso, Anna Bicchi, Elena De Momi, Xiu Zhang et al.
2 citations
IEEE Transactions on Medical Robotics and Bionics
Cardiac Valve Diseases and Treatments
2.78
article

Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair

Angela Peloso, Anna Bicchi, Elena De Momi, Xiu Zhang, Benjamín Ignacio Fortuño Jara, Vanessa Cannizzaro
article en
2 citations

Abstract

Minimally invasive mitral valve repair offers significant advantages over traditional open-heart surgery, yet it remains a complex procedure that exposes both patients and medical staff to radiation. To address these challenges, a significant research interest is growing in automating these manual procedures. Continuum robots represent a promising approach, thanks to their ability to navigate confined spaces. However, their nonlinear behavior presents challenges in modeling and control. In this study, we developed a robust position control method for a variable-length tendon-driven continuum robot. We designed a control system that effectively tracks the desired target positions by employing a constant curvature model and a Jacobian-based control algorithm with real-time position feedback. We assessed the stability of our system through Lyapunov analysis, demonstrating reliable convergence to these target positions. Experimental validation conducted in a cardiovascular phantom demonstrated significant improvements with respect to the state of the art. Our method achieved a trajectory following error of approximately 2.43 mm [1.63, 3.23] and a target position error of about 1.92 mm [1.73, 3.13]. Moreover, the computation time per trajectory point was reduced to approximately 0.04 seconds, highlighting enhanced computational efficiency. These results showcase improved accuracy and efficiency in minimally invasive mitral valve repair procedures.

IEEE Transactions on Medical Robotics and BionicsVol. 7(2)
Politecnico di Milano (IT)
Openalex Percentile: Top 11%
Cardiac Valve Diseases and Treatments
2.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.