Real-Time Detection of D-Glucose Molecules in Exhaled Aerosols Using a Biochemical Sensor for Breathalyzer Applications

The growing prevalence of chronic diseases, such as diabetes, underscores the need for rapid, noninvasive monitoring technologies, as conventional methods are frequently invasive. Exhaled breath aerosol provides a noninvasive alternative to blood sampling for glucose monitoring, but its dilute nature demands highly sensitive sensors for micromolar-level detection. This study presents a novel biosensor utilizing a molecularly imprinted polymer designed to selectively target D-glucose molecules from exhaled breath aerosols. The sensor underwent thorough testing across a range of aerosolized glucose concentrations and was validated using exhaled breath condensate (EBC) samples from healthy subjects, utilizing a 3-D printed breathalyzer device. The findings demonstrate a significant correlation between D-glucose levels in EBC (aerosols) and sensor resistance.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2025-03-12
DOI
https://doi.org/10.1109/lsens.2025.3546084
Citations
1
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Detection of D-Glucose Molecules in Exhaled Aerosols Using a Biochemical Sensor for Breathalyzer Applications

Rui Huang, Juntong Chen, Nader Lobandi, Nian X. Sun et al.
1 citations
IEEE Sensors Letters
Advanced Chemical Sensor Technologies
0.67
article

Real-Time Detection of D-Glucose Molecules in Exhaled Aerosols Using a Biochemical Sensor for Breathalyzer Applications

Rui Huang, Juntong Chen, Nader Lobandi, Nian X. Sun, Pardis Sadeghi, William Sun, Bin Luo, Rania Alshawabkeh, Amie Rui
article en
1 citations

Abstract

The growing prevalence of chronic diseases, such as diabetes, underscores the need for rapid, noninvasive monitoring technologies, as conventional methods are frequently invasive. Exhaled breath aerosol provides a noninvasive alternative to blood sampling for glucose monitoring, but its dilute nature demands highly sensitive sensors for micromolar-level detection. This study presents a novel biosensor utilizing a molecularly imprinted polymer designed to selectively target D-glucose molecules from exhaled breath aerosols. The sensor underwent thorough testing across a range of aerosolized glucose concentrations and was validated using exhaled breath condensate (EBC) samples from healthy subjects, utilizing a 3-D printed breathalyzer device. The findings demonstrate a significant correlation between D-glucose levels in EBC (aerosols) and sensor resistance.

IEEE Sensors LettersVol. 9(4)
Northeastern University (US), Brown University (US), Ferro (United States) (US)
Openalex Percentile: Top 34%
Advanced Chemical Sensor Technologies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.