From the Editor

This issue features three articles, the first of which is “Advancing Space Charge Test Techniques: Pulsed Electro-Acoustic Measurement on a 525-kV HVDC Cable.” The aim of this article is to validate the procedure of assessing the effect of space charge accumulation in extruded HVDC cables. The article presents the results of a pulsed electro-acoustic (PEA) measurement following the protocol recommended by IEEE standard 1732–2017 (IEEE Recommended Practice for Space Charge Measurements on High-Voltage Direct-Current Extruded Cables for Rated Voltages up to 550 kV). A full-size, unaged HVDC cable rated to 525 kV was the chosen sample, with two tests conducted in positive and negative DC polarities. This study demonstrates the reproducibility of the PEA measurement on full-size HVDC cables over 100 meters in length and the applicability of the PEA measurement protocol in the IEEE standard 1732-2017.

Authors

Publication Details

Journal
IEEE Electrical Insulation Magazine
Published
2025-03-01
DOI
https://doi.org/10.1109/mei.2025.10924658
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From the Editor

Tony Lujia Chen
2 links
IEEE Electrical Insulation Magazine
High voltage insulation and dielectric phenomena
article

From the Editor

Tony Lujia Chen
article en

Abstract

This issue features three articles, the first of which is “Advancing Space Charge Test Techniques: Pulsed Electro-Acoustic Measurement on a 525-kV HVDC Cable.” The aim of this article is to validate the procedure of assessing the effect of space charge accumulation in extruded HVDC cables. The article presents the results of a pulsed electro-acoustic (PEA) measurement following the protocol recommended by IEEE standard 1732–2017 (IEEE Recommended Practice for Space Charge Measurements on High-Voltage Direct-Current Extruded Cables for Rated Voltages up to 550 kV). A full-size, unaged HVDC cable rated to 525 kV was the chosen sample, with two tests conducted in positive and negative DC polarities. This study demonstrates the reproducibility of the PEA measurement on full-size HVDC cables over 100 meters in length and the applicability of the PEA measurement protocol in the IEEE standard 1732-2017.

IEEE Electrical Insulation MagazineVol. 41(2)
Openalex Percentile: Top 97%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.