Nuclear radiation attenuation properties of PbO-doped polymeric composites

Abstract The current study is subjected to examine six synthesized polymeric samples (SPS); XPbO:(45-X)B 2 O 3 –05ZnO–50C 2 H 3 Cl ; (where x = 10–35 wt.%, step size of 5%) towards radiation attenuation as a comparative study. The investigated samples were characterized using XRD, FTIR, and SEM. The radiation attenuation performance was assessed using the Monte Carlo simulation code (MC) and validated using PhyX software. The amount of PbO in SPS was addressed through the radiation shielding by various parameters (e.g., linear attenuation coefficients ( µ ), etc.) in the photon energy from 0.015 to 15 MeV. In addition, the Fast Neutrons Removal Cross Sections (FNRCS) were determined. The values of µ were varied from (29.8451 to 0.0372), (39.0225 to 0.0422), (50.8618 to 0.0477), (67.3618 to 0.0583), (72.3134 to 0.0581), and (85.6818 to 0.0647) cm −1 for the SPS [10PbO:35B 2 O 3 ], [15PbO:30B 2 O 3 ], [20PbO:25B 2 O 3 ], [25PbO:20B 2 O 3 ], [30PbO:15B 2 O 3 ], and [35PbO:10B 2 O 3 ], respectively at photon-energy up to 15 MeV. The sample [35PbO:10B 2 O 3 ] has the highest µ values because of PbO content (35%) and high density. The FNRCS values for the SPS were ranged from 00.77 to 00.88 cm −1 . The sample [25PbO:20B 2 O 3 ] has the highest value of FNRCS. The findings indicated the significant attenuation of γ -rays and neutrons radiation shielding potential of materials doped with PbO and showed that they should be used in radiological protection.

Authors

Institutions

Publication Details

Journal
Journal of Materials Science Materials in Electronics
Published
2025-03-01
DOI
https://doi.org/10.1007/s10854-025-14372-3
Citations
7
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
3.62
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nuclear radiation attenuation properties of PbO-doped polymeric composites

A. M. Abdelghany, Hesham. A. Yousef, Mohamed Mitwalli, Islam M. Nabil
7 citations
Journal of Materials Science Materials in Electronics
Radiation Shielding Materials Analysis
3.62
article

Nuclear radiation attenuation properties of PbO-doped polymeric composites

A. M. Abdelghany, Hesham. A. Yousef, Mohamed Mitwalli, Islam M. Nabil
article en
7 citations

Abstract

Abstract The current study is subjected to examine six synthesized polymeric samples (SPS); XPbO:(45-X)B 2 O 3 –05ZnO–50C 2 H 3 Cl ; (where x = 10–35 wt.%, step size of 5%) towards radiation attenuation as a comparative study. The investigated samples were characterized using XRD, FTIR, and SEM. The radiation attenuation performance was assessed using the Monte Carlo simulation code (MC) and validated using PhyX software. The amount of PbO in SPS was addressed through the radiation shielding by various parameters (e.g., linear attenuation coefficients ( µ ), etc.) in the photon energy from 0.015 to 15 MeV. In addition, the Fast Neutrons Removal Cross Sections (FNRCS) were determined. The values of µ were varied from (29.8451 to 0.0372), (39.0225 to 0.0422), (50.8618 to 0.0477), (67.3618 to 0.0583), (72.3134 to 0.0581), and (85.6818 to 0.0647) cm −1 for the SPS [10PbO:35B 2 O 3 ], [15PbO:30B 2 O 3 ], [20PbO:25B 2 O 3 ], [25PbO:20B 2 O 3 ], [30PbO:15B 2 O 3 ], and [35PbO:10B 2 O 3 ], respectively at photon-energy up to 15 MeV. The sample [35PbO:10B 2 O 3 ] has the highest µ values because of PbO content (35%) and high density. The FNRCS values for the SPS were ranged from 00.77 to 00.88 cm −1 . The sample [25PbO:20B 2 O 3 ] has the highest value of FNRCS. The findings indicated the significant attenuation of γ -rays and neutrons radiation shielding potential of materials doped with PbO and showed that they should be used in radiological protection.

Journal of Materials Science Materials in ElectronicsVol. 36(8)
Damietta University (EG), Suez University (EG), Mansoura University (EG), National Research Centre (EG), Fayoum University (EG)
Openalex Percentile: Top 7%
Radiation Shielding Materials Analysis
3.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Nuclear radiation attenuation properties of PbO-doped polymeric composites — A. M. Abdelghany, Hesham. A. Yousef, et al. · Journal of Materials Science Materials in Electronics (2025) | TGRS Research Map | TGRS