Functional Near-Infrared Spectroscopy Feature Extraction with Application in Workload Estimation

Functional near-infrared spectroscopy (fNIRS) is a brain imaging technique used to estimate neuronal activity by measuring blood oxygenation. In this paper, we develop and evaluate an extensive set of fNIRS features for workload estimation, combining them with respiration and heartbeat signals. Our subject- and session-independent workload estimator is validated in a virtual flight simulator, where workload is objectively assessed based on task performance. We experiment with various regression models and feature ablations, identifying the most effective fNIRS features. The best fNIRS-based model achieves a correlation of 0.3188 with objective workload labels, improving to 0.3268 when incorporating breathing signals. This study demonstrates the value of our novel fNIRS feature set for workload estimation.

Authors

Institutions

Publication Details

Published
2025-03-12
DOI
https://doi.org/10.1109/icassp49660.2025.10888530
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Functional Near-Infrared Spectroscopy Feature Extraction with Application in Workload Estimation

Ivan Tashev, Elisabeth R. M. Heremans, Dimitra Emmanouilidou, Andre Golard et al.
2 citations
Non-Invasive Vital Sign Monitoring
1.35
article

Functional Near-Infrared Spectroscopy Feature Extraction with Application in Workload Estimation

Ivan Tashev, Elisabeth R. M. Heremans, Dimitra Emmanouilidou, Andre Golard, Ryen W. White, David Johnston
article en
2 citations

Abstract

Functional near-infrared spectroscopy (fNIRS) is a brain imaging technique used to estimate neuronal activity by measuring blood oxygenation. In this paper, we develop and evaluate an extensive set of fNIRS features for workload estimation, combining them with respiration and heartbeat signals. Our subject- and session-independent workload estimator is validated in a virtual flight simulator, where workload is objectively assessed based on task performance. We experiment with various regression models and feature ablations, identifying the most effective fNIRS features. The best fNIRS-based model achieves a correlation of 0.3188 with objective workload labels, improving to 0.3268 when incorporating breathing signals. This study demonstrates the value of our novel fNIRS feature set for workload estimation.

Microsoft (United States) (US)
Openalex Percentile: Top 22%
Non-Invasive Vital Sign Monitoring
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Functional Near-Infrared Spectroscopy Feature Extraction with Application in Workload Estimation — Ivan Tashev, Elisabeth R. M. Heremans, et al. · (2025) | TGRS Research Map | TGRS