Evaluating the Posterior Sampling Ability of Plug&Play Diffusion Methods in Sparse-View CT

Plug&Play (PnP) diffusion models are state-of-the-art methods in computed tomography (CT) reconstruction. Such methods usually consider applications where the sinogram contains a sufficient amount of information for the posterior distribution to be concentrated around a single mode, and consequently are evaluated using image-to-image metrics such as PSNR/SSIM. Instead, we are interested in reconstructing compressible flow images from sinograms having a small number of projections, which results in a posterior distribution no longer concentrated or even multimodal. Thus, in this paper, we aim at evaluating the approximate posterior of PnP diffusion models and introduce two posterior evaluation properties. We quantitatively evaluate three PnP diffusion methods on three different datasets for several numbers of projections. We surprisingly find that, for each method, the approximate posterior deviates from the true posterior when the number of projections decreases.

Authors

Institutions

Publication Details

Published
2025-03-12
DOI
https://doi.org/10.1109/icassp49660.2025.10888207
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Posterior Sampling Ability of Plug&Play Diffusion Methods in Sparse-View CT

Guillaume Bourmaud, Frédéric Champagnat, Jean‐François Giovannelli, Liam Moroy
Advanced X-ray and CT Imaging
article

Evaluating the Posterior Sampling Ability of Plug&Play Diffusion Methods in Sparse-View CT

Guillaume Bourmaud, Frédéric Champagnat, Jean‐François Giovannelli, Liam Moroy
article en

Abstract

Plug&Play (PnP) diffusion models are state-of-the-art methods in computed tomography (CT) reconstruction. Such methods usually consider applications where the sinogram contains a sufficient amount of information for the posterior distribution to be concentrated around a single mode, and consequently are evaluated using image-to-image metrics such as PSNR/SSIM. Instead, we are interested in reconstructing compressible flow images from sinograms having a small number of projections, which results in a posterior distribution no longer concentrated or even multimodal. Thus, in this paper, we aim at evaluating the approximate posterior of PnP diffusion models and introduce two posterior evaluation properties. We quantitatively evaluate three PnP diffusion methods on three different datasets for several numbers of projections. We surprisingly find that, for each method, the approximate posterior deviates from the true posterior when the number of projections decreases.

Centre National de la Recherche Scientifique (FR), Université de Bordeaux (FR), Université Paris-Saclay (FR), Laboratoire de l'Intégration du Matériau au Système (FR), Institut Polytechnique de Bordeaux (FR)
Openalex Percentile: Top 96%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.