Integration of thin layer chromatography and smartphone-based colorimetric analysis for the detection of barbiturates

• Developed a novel TLC and smartphone-based colorimetric method for barbiturate detection • Optimized phenobarbital extraction under acidic conditions for maximum recovery • Consistent hRf values (58.4–65.0, 63.2–63.7) achieved with TLC. • Blue RGB intensity proved reliability for quantification • Validated with high specificity, precision, (RSD < 5%), and linearity (R² > 0.99). • Cost-effective and portable with applications in forensic and clinical settings. Barbiturates, a key class of psychoactive drugs, present challenges in accurate detection due to their misuse and involvement in forensic investigations. This study introduces an innovative approach combining Thin Layer Chromatography (TLC) and smartphone-based colorimetric analysis for detecting and quantifying barbiturates extracts. Phenobarbital was extracted using liquid-liquid extraction across acidic, basic, and neutral pH levels, with optimal recovery observed in acidic conditions. TLC plates were fabricated and developed by using a chloroform-acetone solvent system (80:20), and spots were visualized using mercuric chloride diphenyl carbazone. Results showed that barbiturates extraction was highly effective in acidic conditions with hRf value for phenobarbital ranging from 58.4 to 65.0 on plate 1 and 63.2 to 63.7 on plate 2, demonstrating high consistency. RGB analysis revealed that blue color intensity was the most reliable for phenobarbital identification, with average intensities of 208 (standard) and 187.75 (samples) on plate 1 and 208.75 (samples) on plate 2. These findings, supported by validation showing specificity, linearity (R2>0.99), and precision (RSD<5%), demonstrate that integrating TLC with smartphone-based colorimetry offers a cost-effective, portable and reliable method for barbiturate analysis, with significant implications for forensic and clinical applications.

Authors

Institutions

Publication Details

Journal
Green Analytical Chemistry
Published
2025-03-12
DOI
https://doi.org/10.1016/j.greeac.2025.100246
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integration of thin layer chromatography and smartphone-based colorimetric analysis for the detection of barbiturates

Keneuoe Letumanyane, Elisa Kalugendo
Green Analytical Chemistry
Advanced Chemical Sensor Technologies
article

Integration of thin layer chromatography and smartphone-based colorimetric analysis for the detection of barbiturates

Keneuoe Letumanyane, Elisa Kalugendo
article en

Abstract

• Developed a novel TLC and smartphone-based colorimetric method for barbiturate detection • Optimized phenobarbital extraction under acidic conditions for maximum recovery • Consistent hRf values (58.4–65.0, 63.2–63.7) achieved with TLC. • Blue RGB intensity proved reliability for quantification • Validated with high specificity, precision, (RSD < 5%), and linearity (R² > 0.99). • Cost-effective and portable with applications in forensic and clinical settings. Barbiturates, a key class of psychoactive drugs, present challenges in accurate detection due to their misuse and involvement in forensic investigations. This study introduces an innovative approach combining Thin Layer Chromatography (TLC) and smartphone-based colorimetric analysis for detecting and quantifying barbiturates extracts. Phenobarbital was extracted using liquid-liquid extraction across acidic, basic, and neutral pH levels, with optimal recovery observed in acidic conditions. TLC plates were fabricated and developed by using a chloroform-acetone solvent system (80:20), and spots were visualized using mercuric chloride diphenyl carbazone. Results showed that barbiturates extraction was highly effective in acidic conditions with hRf value for phenobarbital ranging from 58.4 to 65.0 on plate 1 and 63.2 to 63.7 on plate 2, demonstrating high consistency. RGB analysis revealed that blue color intensity was the most reliable for phenobarbital identification, with average intensities of 208 (standard) and 187.75 (samples) on plate 1 and 208.75 (samples) on plate 2. These findings, supported by validation showing specificity, linearity (R2>0.99), and precision (RSD<5%), demonstrate that integrating TLC with smartphone-based colorimetry offers a cost-effective, portable and reliable method for barbiturate analysis, with significant implications for forensic and clinical applications.

Green Analytical ChemistryVol. 13
National Forensic Sciences University (IN), Central Forensic Science Laboratory (IN), Forensic Sciences Department (IN)
Openalex Percentile: Top 96%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.