Trapped Guide Extension Catheter Technique for Management of Coronary Artery Perforation in a Balloon Uncrossable Lesion
The potential pitfalls include the following: 1) prolonged inflation of trapping balloon may cause ischemia and hypotension, and 2) caution when used in proximal vessels that subtend a large area of the myocardium. Excessively high-pressure inflation of the trapping balloon may damage the coronary artery.
Authors
- Jonathan Jiunn Liang Yap (ORCID: https://orcid.org/0000-0002-5227-8536)
- Ningyan Wong (ORCID: https://orcid.org/0000-0001-8717-3614)
- Paul Jie Wen Tern (ORCID: https://orcid.org/0000-0001-5382-9881)
- Shoji Sagrado Mantilla
Institutions
- Duke-NUS Medical School (SG)
- National Heart Centre Singapore (SG)
- Sengkang General Hospital (SG)
Publication Details
- Journal
- JACC Case Reports
- Published
- 2025-03-12
- DOI
- https://doi.org/10.1016/j.jaccas.2025.103288
- Primary Topic
- Coronary Interventions and Diagnostics
- Type
- article
- Field-Weighted Citation Impact
- 0.00