Preparation and characterization of a certified reference material of toxic elements in cannabis leaves

The quantification of harmful elements in cannabis is a relevant analytical task that requires metrological tools to ensure the reliability of the measurement results. This work reports the preparation and characterization of a certified reference material (CRM) for toxic elements-arsenic (As), cadmium (Cd), and lead (Pb)-in pulverized, lyophilized cannabis leaf tissue. To prepare the CRM INM-040-1, a portion of dried ground cannabis vegetal material was spiked with the elements at mass fraction values close to the levels of interest in relevant regulations for this kind of matrix: 0.34 mg/kg for arsenic, 0.34 mg/kg for cadmium, and 0.66 mg/kg for lead. The elements were quantified by inductively coupled plasma mass spectrometry (ICP-MS) in combination with graphite furnace atomic absorption spectroscopy (GF-AAS, for cadmium and lead) or hydride generation atomic absorption spectroscopy (HG-AAS, for arsenic). The analytical calibration was done by gravimetric standard addition for ICP-MS and GF-AAS, while bracketing calibration was used for HG-AAS. Furthermore, internal standard correction was used during ICP-MS measurements. The analytical methods were validated to demonstrate their fitness for purpose. The preparation variables of the CRM (particle size, drying treatment, and spiking conditions) were studied to improve the homogeneity of the CRM. The mass fraction of the toxic elements was certified with relative standard uncertainties ranging from 4.2 to 6.9%. The uncertainty contributions considered were the elements' mass fraction measurements, the between-methods bias, the (in)homogeneity of the production batch, and the (in)stability under transport and storage conditions. This new CRM constitutes a useful tool for the laboratories assessing the harmlessness of cannabis materials, promoting humans' safety and regulatory compliance within the medicinal cannabis industry.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2025-03-12
DOI
https://doi.org/10.1007/s00216-025-05809-z
Citations
1
Primary Topic
Heavy Metals in Plants
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation and characterization of a certified reference material of toxic elements in cannabis leaves

Elianna Castillo, Cristhian Paredes, Adriana Rodríguez Ciódaro
1 citations
Analytical and Bioanalytical Chemistry
Heavy Metals in Plants
0.75
article

Preparation and characterization of a certified reference material of toxic elements in cannabis leaves

Elianna Castillo, Cristhian Paredes, Adriana Rodríguez Ciódaro
article en
1 citations

Abstract

The quantification of harmful elements in cannabis is a relevant analytical task that requires metrological tools to ensure the reliability of the measurement results. This work reports the preparation and characterization of a certified reference material (CRM) for toxic elements-arsenic (As), cadmium (Cd), and lead (Pb)-in pulverized, lyophilized cannabis leaf tissue. To prepare the CRM INM-040-1, a portion of dried ground cannabis vegetal material was spiked with the elements at mass fraction values close to the levels of interest in relevant regulations for this kind of matrix: 0.34 mg/kg for arsenic, 0.34 mg/kg for cadmium, and 0.66 mg/kg for lead. The elements were quantified by inductively coupled plasma mass spectrometry (ICP-MS) in combination with graphite furnace atomic absorption spectroscopy (GF-AAS, for cadmium and lead) or hydride generation atomic absorption spectroscopy (HG-AAS, for arsenic). The analytical calibration was done by gravimetric standard addition for ICP-MS and GF-AAS, while bracketing calibration was used for HG-AAS. Furthermore, internal standard correction was used during ICP-MS measurements. The analytical methods were validated to demonstrate their fitness for purpose. The preparation variables of the CRM (particle size, drying treatment, and spiking conditions) were studied to improve the homogeneity of the CRM. The mass fraction of the toxic elements was certified with relative standard uncertainties ranging from 4.2 to 6.9%. The uncertainty contributions considered were the elements' mass fraction measurements, the between-methods bias, the (in)homogeneity of the production batch, and the (in)stability under transport and storage conditions. This new CRM constitutes a useful tool for the laboratories assessing the harmlessness of cannabis materials, promoting humans' safety and regulatory compliance within the medicinal cannabis industry.

Analytical and Bioanalytical ChemistryVol. 417(12)
Universidad Nacional de Colombia (CO)
Industry, innovation and infrastructure
Openalex Percentile: Top 35%
Heavy Metals in Plants
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.