Shear Strength and Serviceability of GFRP-Reinforced Concrete Beams: A Study on Varying Reinforcement Ratios

This study investigates the behavior of GFRP-reinforced concrete beams with varying reinforcement ratios. The experimental program consists of five concrete beams tested under a simply supported four-point bending setup with a section of (250×300) mm and a clear span of 1800 mm with a span-to-depth ratio of 2.3. The beams were reinforced longitudinally with GFRP bars with varying reinforcement ratios (ρ = 0.5, 0.9, 1.35, 1.8, and 2.25) for B1-B5, respectively. GFRP stirrups were used for the transverse direction with a spacing of 240 mm for all the beams. The results showed that raising the GFRP longitudinal reinforcement ratio to 1.35 enhanced load-carrying capacity performance and dropped at higher reinforcement ratios (1.8, 2.25) while offering better performance in controlling crack widths and deflection, which could be due to the limit of bonding with concrete. Increasing the GFRP longitudinal reinforcement ratio reduced the deflection at both service and ultimate loads with enhanced crack control. Lower reinforcement ratios of (ρ= 0.5) resulted in a brittle failure, wider cracks, and poor stiffness. Conversely, a 1.8 reinforcement ratio led to delayed crack initiation, smaller crack widths, and a balanced stiffness-to-ductility ratio being achieved. It was found that the dowel action of longitudinal GFRP bars greatly contributes to the shear strength of concrete beams, with a ratio of (ρ= 1.35) having the maximum load capacity along the tested beams. The ductility index ranged from 1.7 to 2.49. Higher reinforcement ratio beams resulted in a deeper neutral axis up to (ρ = 1.35), demonstrating improved stress distribution and reduced deformations. Doi: 10.28991/CEJ-2025-011-03-04 Full Text: PDF

Authors

Institutions

Publication Details

Journal
Civil Engineering Journal
Published
2025-03-01
DOI
https://doi.org/10.28991/cej-2025-011-03-04
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shear Strength and Serviceability of GFRP-Reinforced Concrete Beams: A Study on Varying Reinforcement Ratios

AbdulMuttalib I. Said, Thar Mohammed Hamed
Civil Engineering Journal
Structural Behavior of Reinforced Concrete
article

Shear Strength and Serviceability of GFRP-Reinforced Concrete Beams: A Study on Varying Reinforcement Ratios

AbdulMuttalib I. Said, Thar Mohammed Hamed
article en

Abstract

This study investigates the behavior of GFRP-reinforced concrete beams with varying reinforcement ratios. The experimental program consists of five concrete beams tested under a simply supported four-point bending setup with a section of (250×300) mm and a clear span of 1800 mm with a span-to-depth ratio of 2.3. The beams were reinforced longitudinally with GFRP bars with varying reinforcement ratios (ρ = 0.5, 0.9, 1.35, 1.8, and 2.25) for B1-B5, respectively. GFRP stirrups were used for the transverse direction with a spacing of 240 mm for all the beams. The results showed that raising the GFRP longitudinal reinforcement ratio to 1.35 enhanced load-carrying capacity performance and dropped at higher reinforcement ratios (1.8, 2.25) while offering better performance in controlling crack widths and deflection, which could be due to the limit of bonding with concrete. Increasing the GFRP longitudinal reinforcement ratio reduced the deflection at both service and ultimate loads with enhanced crack control. Lower reinforcement ratios of (ρ= 0.5) resulted in a brittle failure, wider cracks, and poor stiffness. Conversely, a 1.8 reinforcement ratio led to delayed crack initiation, smaller crack widths, and a balanced stiffness-to-ductility ratio being achieved. It was found that the dowel action of longitudinal GFRP bars greatly contributes to the shear strength of concrete beams, with a ratio of (ρ= 1.35) having the maximum load capacity along the tested beams. The ductility index ranged from 1.7 to 2.49. Higher reinforcement ratio beams resulted in a deeper neutral axis up to (ρ = 1.35), demonstrating improved stress distribution and reduced deformations. Doi: 10.28991/CEJ-2025-011-03-04 Full Text: PDF

Civil Engineering JournalVol. 11(3)
University of Baghdad (IQ)
Openalex Percentile: Top 96%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.