Analysis of electricity measurement accuracy driven by carbon neutrality

In response to the problem of low accuracy in traditional power metering equipment. Driven by the goal of carbon neutrality, This article has designed a high-precision carbon meter based on Time Division Multiplier (TDM) energy metering chip. The design scheme adopts frequency domain analysis method to quantify the errors in TDM structure, eliminating phase shift errors using a modulator with a phase compensation branch; Simultaneously constructed a dynamic carbon emission measurement model for a stepped electric energy meter group, Its principle is to divide the output of the power meter group into multiple intervals, with different carbon emission factors in each interval, to simulate the fluctuation of carbon emission factor values under different output states of the power meter group, and accurately calculate the total carbon emissions of the system; Finally, use LED to display all values. Through experimental verification, the design scheme proposed in this article can effectively achieve power metering driven by carbon neutrality, with an accuracy of 92%.

Authors

Institutions

Publication Details

Journal
Measurement and Control
Published
2025-03-12
DOI
https://doi.org/10.1177/00202940251322001
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of electricity measurement accuracy driven by carbon neutrality

Gong You, Xinggang Li, Qi Li, Liang Yanhe
Measurement and Control
Advanced Electrical Measurement Techniques
article

Analysis of electricity measurement accuracy driven by carbon neutrality

Gong You, Xinggang Li, Qi Li, Liang Yanhe
article en

Abstract

In response to the problem of low accuracy in traditional power metering equipment. Driven by the goal of carbon neutrality, This article has designed a high-precision carbon meter based on Time Division Multiplier (TDM) energy metering chip. The design scheme adopts frequency domain analysis method to quantify the errors in TDM structure, eliminating phase shift errors using a modulator with a phase compensation branch; Simultaneously constructed a dynamic carbon emission measurement model for a stepped electric energy meter group, Its principle is to divide the output of the power meter group into multiple intervals, with different carbon emission factors in each interval, to simulate the fluctuation of carbon emission factor values under different output states of the power meter group, and accurately calculate the total carbon emissions of the system; Finally, use LED to display all values. Through experimental verification, the design scheme proposed in this article can effectively achieve power metering driven by carbon neutrality, with an accuracy of 92%.

Measurement and ControlVol. 59(2)
Heilongjiang Electric Power Workers University (CN)
Openalex Percentile: Top 97%
Advanced Electrical Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.