Revealing the Effects of Tympanic Membrane Implant Mechanical Properties on High‐Frequency Hearing Loss After Clinical Myringoplasty: A Finite Element Analysis

Myringoplasty is most commonly used to treat tympanic membrane (TM) perforation. Clinical data have shown that unexplained high-frequency (above 3 kHz) hearing loss often occurs after myringoplasty. In this paper, a finite element (FE) model of the partial external and middle ear (ME) of the human ear, which considers the actual perforation and TM implants, is developed to reveal the mechanical mechanism of high-frequency hearing loss after implantation of temporalis fascia and cartilage commonly used in myringoplasty. The SFP displacement is proposed to evaluate the myringoplasty effect, which is proved to be better than the current practice of laser Doppler vibrometer (LDV) of umbo vibration. The model-derived results can replicate the phenomenon of better low-frequency (below 1 kHz) hearing recovery and severe high-frequency hearing loss after myringoplasty. Numerical results show that a temporalis fascia and cartilage implant, whose stiffness is smaller compared with normal PT, fails to fully restore hearing above 3 kHz, where higher-order vibration modes appear early, with more severe localization of TM energy and weakening of TM sound transmission. Moreover, the excessive thickness of implants compared to normal pars tensa (PT) leads to a decrease in the first resonant frequency (RF) and the high-frequency magnitude of the SFP displacement. Furthermore, the numerical study shows that TM implants with modulus higher than 45 MPa and density smaller than 1200 kg/m<sup>3</sup> can restore high-frequency hearing better. This study has implications for choosing and designing the appropriate TM implants for myringoplasty.

Authors

Institutions

Publication Details

Journal
International Journal for Numerical Methods in Biomedical Engineering
Published
2025-03-01
DOI
https://doi.org/10.1002/cnm.70028
Citations
1
Primary Topic
Ear Surgery and Otitis Media
Type
article
Field-Weighted Citation Impact
1.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Revealing the Effects of Tympanic Membrane Implant Mechanical Properties on High‐Frequency Hearing Loss After Clinical Myringoplasty: A Finite Element Analysis

Zhanli Liu, Huibin Shi, Jie Wang, Yifeng Li et al.
1 citations
International Journal for Numerical Methods in Biomedical Engineering
Ear Surgery and Otitis Media
1.85
article

Revealing the Effects of Tympanic Membrane Implant Mechanical Properties on High‐Frequency Hearing Loss After Clinical Myringoplasty: A Finite Element Analysis

Zhanli Liu, Huibin Shi, Jie Wang, Yifeng Li, Ziming Yan, Yongtao Sun
article en
1 citations

Abstract

Myringoplasty is most commonly used to treat tympanic membrane (TM) perforation. Clinical data have shown that unexplained high-frequency (above 3 kHz) hearing loss often occurs after myringoplasty. In this paper, a finite element (FE) model of the partial external and middle ear (ME) of the human ear, which considers the actual perforation and TM implants, is developed to reveal the mechanical mechanism of high-frequency hearing loss after implantation of temporalis fascia and cartilage commonly used in myringoplasty. The SFP displacement is proposed to evaluate the myringoplasty effect, which is proved to be better than the current practice of laser Doppler vibrometer (LDV) of umbo vibration. The model-derived results can replicate the phenomenon of better low-frequency (below 1 kHz) hearing recovery and severe high-frequency hearing loss after myringoplasty. Numerical results show that a temporalis fascia and cartilage implant, whose stiffness is smaller compared with normal PT, fails to fully restore hearing above 3 kHz, where higher-order vibration modes appear early, with more severe localization of TM energy and weakening of TM sound transmission. Moreover, the excessive thickness of implants compared to normal pars tensa (PT) leads to a decrease in the first resonant frequency (RF) and the high-frequency magnitude of the SFP displacement. Furthermore, the numerical study shows that TM implants with modulus higher than 45 MPa and density smaller than 1200 kg/m<sup>3</sup> can restore high-frequency hearing better. This study has implications for choosing and designing the appropriate TM implants for myringoplasty.

International Journal for Numerical Methods in Biomedical EngineeringVol. 41(3)
Beijing Tongren Hospital (CN), Tianjin University (CN), Capital Medical University (CN), Tsinghua University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 18%
Ear Surgery and Otitis Media
1.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.