Study on performance of arc rib dew evaporative cooler

In this paper, a new type of dew point evaporative cooler (DP-EC) is designed, the effects of external operation conditions, inlet air velocity ratio, cooling water temperature, arc rib spacing, and arc rib length on cooling efficiency are studied. The results show that when the ratio of working air volume to inlet air velocity is 1.5, the cooling efficiency reaches 126.24%; the arc rib spacing and arc rib length have significant effects on cooling efficiency, reaching maximum at 5mm and 15mm respectively. The cooling efficiency decreases as the cooling water temperature rises. Compared with the traditional structure, the cooling efficiency of the new type of DP-EC is increased by 10.32%, 25.82%, and 13.87%, respectively, under the condition of changing the inlet temperature, ambient humidity and inlet speed.

Authors

Institutions

Publication Details

Published
2025-03-05
DOI
https://doi.org/10.1117/12.3060056
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on performance of arc rib dew evaporative cooler

Guangxu Zhou, Shengli Zhang, Fei Ma, Junfeng Hou et al.
Refrigeration and Air Conditioning Technologies
article

Study on performance of arc rib dew evaporative cooler

Guangxu Zhou, Shengli Zhang, Fei Ma, Junfeng Hou, Yucao Wang
article en

Abstract

In this paper, a new type of dew point evaporative cooler (DP-EC) is designed, the effects of external operation conditions, inlet air velocity ratio, cooling water temperature, arc rib spacing, and arc rib length on cooling efficiency are studied. The results show that when the ratio of working air volume to inlet air velocity is 1.5, the cooling efficiency reaches 126.24%; the arc rib spacing and arc rib length have significant effects on cooling efficiency, reaching maximum at 5mm and 15mm respectively. The cooling efficiency decreases as the cooling water temperature rises. Compared with the traditional structure, the cooling efficiency of the new type of DP-EC is increased by 10.32%, 25.82%, and 13.87%, respectively, under the condition of changing the inlet temperature, ambient humidity and inlet speed.

Zhengzhou University of Light Industry (CN), China Tobacco (CN)
Openalex Percentile: Top 96%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on performance of arc rib dew evaporative cooler — Guangxu Zhou, Shengli Zhang, et al. · (2025) | TGRS Research Map | TGRS