Improving the Performance of Holter ECG Monitor with Digital Filter Comparison Method for Motion Artifact Reduction

Holter ECG monitor is a device that records the patient's heart activity throughout the day, but the patient's body movements can cause artifacts that interfere with ECG signal quality. This study aims to improve the performance of Holter Monitor by comparing Infinite Impulse Response (IIR) and Finite Impulse Response (FIR) filters in reducing motion artifacts. Filters were applied at various orders using Butterworth and Window methods. Analysis was performed with Fast Fourier Transform (FFT) to evaluate the effectiveness of the filters in reducing artifacts. The results show that digital filters significantly reduce motion artifacts. FIR filters at high orders (6 and 8) provide a more stable signal with an average SNR value of 10.3282 at order 8. While the IIR filters at low orders (2 and 4) with an average SNR of 12.0281 at order 2, reduced the artifacts well, but at high orders were unstable and resulted in signal distortion. This research is expected to assist medical personnel in analyzing better heart signal data and improve the quality of portable heart monitoring for patients undergoing daily activities, while enabling more efficient data transmission without removing the SD Card.

Authors

Institutions

Publication Details

Journal
Jurnal Teknokes
Published
2024-12-30
DOI
https://doi.org/10.35882/k57drr92
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving the Performance of Holter ECG Monitor with Digital Filter Comparison Method for Motion Artifact Reduction

HELENORA TOAN
Jurnal Teknokes
Non-Invasive Vital Sign Monitoring
article

Improving the Performance of Holter ECG Monitor with Digital Filter Comparison Method for Motion Artifact Reduction

HELENORA TOAN
article en

Abstract

Holter ECG monitor is a device that records the patient's heart activity throughout the day, but the patient's body movements can cause artifacts that interfere with ECG signal quality. This study aims to improve the performance of Holter Monitor by comparing Infinite Impulse Response (IIR) and Finite Impulse Response (FIR) filters in reducing motion artifacts. Filters were applied at various orders using Butterworth and Window methods. Analysis was performed with Fast Fourier Transform (FFT) to evaluate the effectiveness of the filters in reducing artifacts. The results show that digital filters significantly reduce motion artifacts. FIR filters at high orders (6 and 8) provide a more stable signal with an average SNR value of 10.3282 at order 8. While the IIR filters at low orders (2 and 4) with an average SNR of 12.0281 at order 2, reduced the artifacts well, but at high orders were unstable and resulted in signal distortion. This research is expected to assist medical personnel in analyzing better heart signal data and improve the quality of portable heart monitoring for patients undergoing daily activities, while enabling more efficient data transmission without removing the SD Card.

Jurnal TeknokesVol. 17(4)
Politeknik Kesehatan Kemenkes Semarang (ID), Eskom (South Africa) (ZA)
Openalex Percentile: Top 75%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improving the Performance of Holter ECG Monitor with Digital Filter Comparison Method for Motion Artifact Reduction — HELENORA TOAN · Jurnal Teknokes (2024) | TGRS Research Map | TGRS