Heat Field Characteristics of Solid Domain of Nozzle Flowmeter with Different Weld Structures

In this paper, four weld structures with a total of 10 distinct welds were produced and the effect of weld structures on the heat flow field within the solid wall of the nozzle flowmeter is thoroughly investigated by numerical calculations. The results show that, on the path from upstream to downstream, the distance between the weld and nozzle, the width below the weld, the taper angle and the opening have less influence on the heat flow distribution. On the path from the inner to the outer wall, the taper angle and the opening have a greater effect on the peak and the maximum magnitude of the total heat flow, and the peak and the maximum magnitude of the total heat flow for big taper angle and opening welds are much bigger than those under small taper angle and opening welds. The distance between the weld and nozzle, the width below the weld, the taper angle and the opening significantly affect the heat flow distribution of the path section near 0.2 times the length of the monitoring path. However, the heat flow distribution inside the nozzle flowmeter is minimally affected by the distance between the weld and nozzle, the width below the weld, the taper angle and the opening.

Institutions

Publication Details

Journal
International Journal for Engineering Modelling
Published
2025-03-11
DOI
https://doi.org/10.31534/engmod.2025.1.ri.06v
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat Field Characteristics of Solid Domain of Nozzle Flowmeter with Different Weld Structures

International Journal for Engineering Modelling
Flow Measurement and Analysis
article

Heat Field Characteristics of Solid Domain of Nozzle Flowmeter with Different Weld Structures

article en

Abstract

In this paper, four weld structures with a total of 10 distinct welds were produced and the effect of weld structures on the heat flow field within the solid wall of the nozzle flowmeter is thoroughly investigated by numerical calculations. The results show that, on the path from upstream to downstream, the distance between the weld and nozzle, the width below the weld, the taper angle and the opening have less influence on the heat flow distribution. On the path from the inner to the outer wall, the taper angle and the opening have a greater effect on the peak and the maximum magnitude of the total heat flow, and the peak and the maximum magnitude of the total heat flow for big taper angle and opening welds are much bigger than those under small taper angle and opening welds. The distance between the weld and nozzle, the width below the weld, the taper angle and the opening significantly affect the heat flow distribution of the path section near 0.2 times the length of the monitoring path. However, the heat flow distribution inside the nozzle flowmeter is minimally affected by the distance between the weld and nozzle, the width below the weld, the taper angle and the opening.

International Journal for Engineering ModellingVol. 38(1)
Quzhou College of Technology (CN), Quzhou University (CN), Hunan University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 95%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.