A method in non-destructive testing for lead shielding exceeding 25 kg/m2 using 18F

Non-Destructive Testing (NDT) is a commonly used technique for barrier verification within radiation protection, ensuring compliance with national standards and state regulations. There are currently limited published methods in NDT for lead shielding above 25 kg/m<sup>2</sup>, and thus this research aimed to develop a reproducible method to aid in 'in the field' NDT for lead barriers exceeding 25 kg/m<sup>2</sup> using a Fluorine-18 (<sup>18</sup>F) source. Due to the fast decay of <sup>18</sup>F, the data generated within this research was compiled from Monte Carlo (MC) simulations using the PENELOPE engine, and the PENGEOM geometry system to model the proposed empirical setup. The model predicted the Transmission Factor (TF) through area densities (thickness) of lead attenuators up to 302.7 kg/m<sup>2</sup>, with results validated by empirical measurements using a Source-to-Detector Distance (SDD) of 38.1 ± 0.05 cm and 52.7 ± 0.05 cm. However, the study was limited by the chosen activity of <sup>18</sup>F at approximately 180 MBq, where the simulated TF curves demonstrated correspondence of data up to and including area densities of 162.4 kg/m<sup>2</sup> using a 38.1 ± 0.05 cm SDD, and 138.0 kg/m<sup>2</sup> with a 52.7 ± 0.05 cm SDD. Beyond these thicknesses, the empirical transmission curves deviated from simulated curves due to measurable transmissions becoming significantly reduced. This research demonstrated that using SDDs above 23 cm would provide sufficient near narrow beam conditions with the proposed experimental configuration for in-the-field NDT. The research aimed to develop an equation and method for NDT using a <sup>18</sup>F source for lead barriers greater than 25 kg/m<sup>2</sup>, with transmission data to be made available upon request to the author.

Authors

Institutions

Publication Details

Journal
Physical and Engineering Sciences in Medicine
Published
2025-03-11
DOI
https://doi.org/10.1007/s13246-025-01524-2
Primary Topic
Nuclear and radioactivity studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A method in non-destructive testing for lead shielding exceeding 25 kg/m2 using 18F

Jason Tse, Enda Ryan, Jeremy Berrell, Deborah Carrick
Physical and Engineering Sciences in Medicine
Nuclear and radioactivity studies
article

A method in non-destructive testing for lead shielding exceeding 25 kg/m2 using 18F

Jason Tse, Enda Ryan, Jeremy Berrell, Deborah Carrick
article en

Abstract

Non-Destructive Testing (NDT) is a commonly used technique for barrier verification within radiation protection, ensuring compliance with national standards and state regulations. There are currently limited published methods in NDT for lead shielding above 25 kg/m<sup>2</sup>, and thus this research aimed to develop a reproducible method to aid in 'in the field' NDT for lead barriers exceeding 25 kg/m<sup>2</sup> using a Fluorine-18 (<sup>18</sup>F) source. Due to the fast decay of <sup>18</sup>F, the data generated within this research was compiled from Monte Carlo (MC) simulations using the PENELOPE engine, and the PENGEOM geometry system to model the proposed empirical setup. The model predicted the Transmission Factor (TF) through area densities (thickness) of lead attenuators up to 302.7 kg/m<sup>2</sup>, with results validated by empirical measurements using a Source-to-Detector Distance (SDD) of 38.1 ± 0.05 cm and 52.7 ± 0.05 cm. However, the study was limited by the chosen activity of <sup>18</sup>F at approximately 180 MBq, where the simulated TF curves demonstrated correspondence of data up to and including area densities of 162.4 kg/m<sup>2</sup> using a 38.1 ± 0.05 cm SDD, and 138.0 kg/m<sup>2</sup> with a 52.7 ± 0.05 cm SDD. Beyond these thicknesses, the empirical transmission curves deviated from simulated curves due to measurable transmissions becoming significantly reduced. This research demonstrated that using SDDs above 23 cm would provide sufficient near narrow beam conditions with the proposed experimental configuration for in-the-field NDT. The research aimed to develop an equation and method for NDT using a <sup>18</sup>F source for lead barriers greater than 25 kg/m<sup>2</sup>, with transmission data to be made available upon request to the author.

Physical and Engineering Sciences in MedicineVol. 48(2)
Queensland Health (AU), Queensland University of Technology (AU), Gold Coast Hospital (AU), Prince Charles Hospital (AU), Children's Health Queensland Hospital and Health Service (AU)
Queensland University of Technology
Openalex Percentile: Top 95%
Nuclear and radioactivity studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.