Pre-Test of a Stand for Testing Fire Resistance of Compressed Hydrogen Storage Systems

The publication presents methods and pre-test results of a stand for testing CHSS in terms of resistance to open fire. The basis for the conducted research is the applicable provisions contained in the UN/ECE Regulation R134. The study includes an overview of contemporary solutions for hydrogen storage systems in high-pressure tanks in means of transport. Development in this area is a response to the challenge of reducing global carbon dioxide emissions and limiting the emissions of toxic compounds. The variety of storage systems used is driven by constraints, including energy demand and available space. New tank designs and conducted tests allow for an improvement in systems in terms of their functionality and safety. Today, the advancement of modern technologies for producing high-pressure tanks allows for the use of working pressures up to 70 MPa. The main goal of the presented research is to present the requirements and research methodology verifying the tank structure and the security systems used in open-fire conditions. These tests are the final stage of the approval process for individual pressure vessels or complete hydrogen storage systems. Their essence is to eliminate the occurrence of an explosion in the event of a fire.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-03-11
DOI
https://doi.org/10.3390/en18061368
Citations
1
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
4.99
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pre-Test of a Stand for Testing Fire Resistance of Compressed Hydrogen Storage Systems

M. Flekiewicz, Grzegorz Kubica, Paweł Fabiś, Piotr Hemlecki et al.
1 citations
Energies
Combustion and Detonation Processes
4.99
article

Pre-Test of a Stand for Testing Fire Resistance of Compressed Hydrogen Storage Systems

M. Flekiewicz, Grzegorz Kubica, Paweł Fabiś, Piotr Hemlecki, Paweł Marzec
article en
1 citations

Abstract

The publication presents methods and pre-test results of a stand for testing CHSS in terms of resistance to open fire. The basis for the conducted research is the applicable provisions contained in the UN/ECE Regulation R134. The study includes an overview of contemporary solutions for hydrogen storage systems in high-pressure tanks in means of transport. Development in this area is a response to the challenge of reducing global carbon dioxide emissions and limiting the emissions of toxic compounds. The variety of storage systems used is driven by constraints, including energy demand and available space. New tank designs and conducted tests allow for an improvement in systems in terms of their functionality and safety. Today, the advancement of modern technologies for producing high-pressure tanks allows for the use of working pressures up to 70 MPa. The main goal of the presented research is to present the requirements and research methodology verifying the tank structure and the security systems used in open-fire conditions. These tests are the final stage of the approval process for individual pressure vessels or complete hydrogen storage systems. Their essence is to eliminate the occurrence of an explosion in the event of a fire.

EnergiesVol. 18(6)
Silesian University of Technology (PL)
Openalex Percentile: Top 7%
Combustion and Detonation Processes
4.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.