Efficient reconstruction and calibration strategy for a uniaxial MEMS-based 3D reconstruction system

The micro-electro-mechanical system (MEMS) has the advantages of high frequency and low size, and the uniaxial MEMS-based 3D measurement system has attracted much attention. However, the reconstruction and calibration processes of existing methods are complicated. In this paper, an efficient 3D reconstruction method is proposed. First, the MEMS coordinate system (MCS) is established according to the mathematical model of the MEMS mirror, then the simple constraint is obtained in the MCS, and the 3D points are recovered in a triangulation-like form. Furthermore, a simple calibration method for the MCS is proposed, which requires only one calibration position to complete the calibration, greatly simplifying the calibration process. Quantitative and comparative experiments verify the feasibility and effectiveness of the proposed method.

Authors

Institutions

Publication Details

Journal
Applied Optics
Published
2025-03-11
DOI
https://doi.org/10.1364/ao.554997
Citations
1
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
1.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient reconstruction and calibration strategy for a uniaxial MEMS-based 3D reconstruction system

Zhen Peng, Yao Wang, Yuchen Han, Ziang Chen et al.
1 citations
Applied Optics
Optical measurement and interference techniques
1.28
article

Efficient reconstruction and calibration strategy for a uniaxial MEMS-based 3D reconstruction system

Zhen Peng, Yao Wang, Yuchen Han, Ziang Chen, Zhonghui Chen, Lin Bin, Wang Hengyu
article en
1 citations

Abstract

The micro-electro-mechanical system (MEMS) has the advantages of high frequency and low size, and the uniaxial MEMS-based 3D measurement system has attracted much attention. However, the reconstruction and calibration processes of existing methods are complicated. In this paper, an efficient 3D reconstruction method is proposed. First, the MEMS coordinate system (MCS) is established according to the mathematical model of the MEMS mirror, then the simple constraint is obtained in the MCS, and the 3D points are recovered in a triangulation-like form. Furthermore, a simple calibration method for the MCS is proposed, which requires only one calibration position to complete the calibration, greatly simplifying the calibration process. Quantitative and comparative experiments verify the feasibility and effectiveness of the proposed method.

Applied OpticsVol. 64(11)
China Electronics Standardization Institute (CN), Zhejiang University (CN), Taizhou University (CN)
National Key Research and Development Program of China
Sustainable cities and communities
Openalex Percentile: Top 23%
Optical measurement and interference techniques
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Efficient reconstruction and calibration strategy for a uniaxial MEMS-based 3D reconstruction system — Zhen Peng, Yao Wang, et al. · Applied Optics (2025) | TGRS Research Map | TGRS