A Beam-Induced Fluorescence Monitor at the Low-Energy Beam Transport Line of the Proton Linac at the Institute for Nuclear Research

A beam-induced fluorescence monitor based on fluorescence of the residual gas in the vacuum pipeline of the accelerator has been installed at the low-energy beam transport line of the INR linac for nondestructive measurements of the proton-beam profile and position. The design features of the monitor and experimental results of measurements during accelerator runs are presented. The monitor sensitivity, accuracy, and resolution are estimated. Based on these estimates, the acceptable operation modes and the necessary parameters of the diagnostic imaging system can be determined for various combinations of the beam parameters and the parameters of the accelerator vacuum system. The feasibility of this type of diagnostics based on a system of standard machine-vision cameras is shown for high-current proton-beam transport lines without the use of image intensifiers and additional gas injection into the pipeline.

Authors

Institutions

Publication Details

Journal
Instruments and Experimental Techniques
Published
2024-12-01
DOI
https://doi.org/10.1134/s0020441224701756
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Beam-Induced Fluorescence Monitor at the Low-Energy Beam Transport Line of the Proton Linac at the Institute for Nuclear Research

Yu. G. Kalinin, S. A. Gavrilov, A. Titov, I. I. Polonik
Instruments and Experimental Techniques
Particle Accelerators and Free-Electron Lasers
article

A Beam-Induced Fluorescence Monitor at the Low-Energy Beam Transport Line of the Proton Linac at the Institute for Nuclear Research

Yu. G. Kalinin, S. A. Gavrilov, A. Titov, I. I. Polonik
article en

Abstract

A beam-induced fluorescence monitor based on fluorescence of the residual gas in the vacuum pipeline of the accelerator has been installed at the low-energy beam transport line of the INR linac for nondestructive measurements of the proton-beam profile and position. The design features of the monitor and experimental results of measurements during accelerator runs are presented. The monitor sensitivity, accuracy, and resolution are estimated. Based on these estimates, the acceptable operation modes and the necessary parameters of the diagnostic imaging system can be determined for various combinations of the beam parameters and the parameters of the accelerator vacuum system. The feasibility of this type of diagnostics based on a system of standard machine-vision cameras is shown for high-current proton-beam transport lines without the use of image intensifiers and additional gas injection into the pipeline.

Instruments and Experimental TechniquesVol. 67(S2)
Moscow Institute of Physics and Technology (RU), Moscow Power Engineering Institute (RU), Institute for Nuclear Research (RU), Moscow Aviation Institute (RU)
Affordable and clean energy
Openalex Percentile: Top 74%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.