Ensuring clock phase repeatability by preventing loss of the 40.078 MHz clock in time-critical detectors: a non-disruptive clock switching approach

Abstract For the High Luminosity phase of the LHC (HL-LHC), the CMS detector electronics require precise and accurate timing to discriminate pileup events. The upgraded Back-End electronics of the Barrel Electromagnetic Calorimeter supply the required high-precision clock (Time Interval Error σ < 5 ps) to the Front-End. However, after a reset is applied on the timing distribution system, the resulting phase of the clock is not accurately repetitive but it gives an up to 10 ps offset for each FPGA node of the timing distribution chain. That is resulting to the uncertainty on the total clock skew with the maximum being N x 10 ps between neighbor channels of the system (where N is the number of FPGA-nodes of the subdetector branch). We have studied a solution minimizing the need to reset the timing distribution system by switching on-the-fly and seamlessly the source clock at the top of the tree to a local LHC-frequency clock. This approach prevents the loss of the links towards the on-detector electronics ensuring clock phase repeatability and offers stability to the on-detectors electronics.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-03-01
DOI
https://doi.org/10.1088/1748-0221/20/03/c03014
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ensuring clock phase repeatability by preventing loss of the 40.078 MHz clock in time-critical detectors: a non-disruptive clock switching approach

A. Svetek, Thomas R. Anderson, T. Gorski, Nikitas Loukas et al.
Journal of Instrumentation
Atomic and Subatomic Physics Research
article

Ensuring clock phase repeatability by preventing loss of the 40.078 MHz clock in time-critical detectors: a non-disruptive clock switching approach

A. Svetek, Thomas R. Anderson, T. Gorski, Nikitas Loukas, L. Moreno, S. Goadhouse, G. Cucciati, Zachariah Thomas Eberle
article en

Abstract

Abstract For the High Luminosity phase of the LHC (HL-LHC), the CMS detector electronics require precise and accurate timing to discriminate pileup events. The upgraded Back-End electronics of the Barrel Electromagnetic Calorimeter supply the required high-precision clock (Time Interval Error σ < 5 ps) to the Front-End. However, after a reset is applied on the timing distribution system, the resulting phase of the clock is not accurately repetitive but it gives an up to 10 ps offset for each FPGA node of the timing distribution chain. That is resulting to the uncertainty on the total clock skew with the maximum being N x 10 ps between neighbor channels of the system (where N is the number of FPGA-nodes of the subdetector branch). We have studied a solution minimizing the need to reset the timing distribution system by switching on-the-fly and seamlessly the source clock at the top of the tree to a local LHC-frequency clock. This approach prevents the loss of the links towards the on-detector electronics ensuring clock phase repeatability and offers stability to the on-detectors electronics.

Journal of InstrumentationVol. 20(03)
University of Notre Dame (US), University of Minnesota (US), University of Wisconsin–Madison (US), Princeton University (US), University of Virginia (US)
Openalex Percentile: Top 97%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.