Bioabsorbable Stent-Covering with Sustained Anticoagulant Activity Fabricated via Alternate Layer-by-Layer Self-Assembly of Heparin and Silk Fibroin

For severe local vasculopathy, covered stents are considered the major medical devices in interventional therapy due to their function to isolate lesions and deliver drugs. However, commercial stent-coverings have unsatisfactory drug-loading capacity and lack bioactivity. Silk fibroin (SF) possesses excellent biocompatibility, biodegradability, and endothelialization ability. In this study, we developed a bioabsorbable SF stent-covering loaded with heparin (Hep) via layer-by-layer self-assembly. Hep was embedded in the stent-covering via interfacial adsorption (Hep-SF) or direct blending with SF (Hep/SF). For interfacial adsorption, the Hep loading capacity increased with adsorption time and Hep concentration, reaching up to 589 μg/cm<sup>2</sup>. All Hep-modified SF stent-coverings were nonhemolytic. After Hep modification, the recalculation time of the Hep-SF stent-covering was significantly prolonged (>2 h), platelet adhesion to its surface was reduced, and no obvious clots formed. Compared to the Hep/SF stent-coverings, the release quantity of Hep from the Hep-SF stent-covering was higher at each time point, regardless of diffusion or enzymatic degradation, but its diffusion release rate was lower than that of the high-dosage Hep/SF stent-covering, suggesting that the Hep-SF stent-covering had more sustained Hep release. Moreover, the released Hep maintained a high anticoagulant activity to significantly prolong activated partial thromboplastin time and thrombin time after long-time diffusion or enzymatic degradation. The results indicated that the Hep-SF stent-covering developed in this study not only had a high loading capacity for anticoagulant drugs (on-demand adjustable) but also could achieve effective and sustained anticoagulant function until the SF material was completely degraded.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2025-03-11
DOI
https://doi.org/10.1021/acsami.4c16643
Citations
5
Primary Topic
Silk-based biomaterials and applications
Type
article
Field-Weighted Citation Impact
2.99

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bioabsorbable Stent-Covering with Sustained Anticoagulant Activity Fabricated via Alternate Layer-by-Layer Self-Assembly of Heparin and Silk Fibroin

Guangzhou Song, Mengnan Dai, Jiannan Wang, Yangxiao Yu et al.
5 citations
ACS Applied Materials & Interfaces
Silk-based biomaterials and applications
2.99
article

Bioabsorbable Stent-Covering with Sustained Anticoagulant Activity Fabricated via Alternate Layer-by-Layer Self-Assembly of Heparin and Silk Fibroin

Guangzhou Song, Mengnan Dai, Jiannan Wang, Yangxiao Yu, Yin Yin, Meng Li
article en
5 citations

Abstract

For severe local vasculopathy, covered stents are considered the major medical devices in interventional therapy due to their function to isolate lesions and deliver drugs. However, commercial stent-coverings have unsatisfactory drug-loading capacity and lack bioactivity. Silk fibroin (SF) possesses excellent biocompatibility, biodegradability, and endothelialization ability. In this study, we developed a bioabsorbable SF stent-covering loaded with heparin (Hep) via layer-by-layer self-assembly. Hep was embedded in the stent-covering via interfacial adsorption (Hep-SF) or direct blending with SF (Hep/SF). For interfacial adsorption, the Hep loading capacity increased with adsorption time and Hep concentration, reaching up to 589 μg/cm<sup>2</sup>. All Hep-modified SF stent-coverings were nonhemolytic. After Hep modification, the recalculation time of the Hep-SF stent-covering was significantly prolonged (>2 h), platelet adhesion to its surface was reduced, and no obvious clots formed. Compared to the Hep/SF stent-coverings, the release quantity of Hep from the Hep-SF stent-covering was higher at each time point, regardless of diffusion or enzymatic degradation, but its diffusion release rate was lower than that of the high-dosage Hep/SF stent-covering, suggesting that the Hep-SF stent-covering had more sustained Hep release. Moreover, the released Hep maintained a high anticoagulant activity to significantly prolong activated partial thromboplastin time and thrombin time after long-time diffusion or enzymatic degradation. The results indicated that the Hep-SF stent-covering developed in this study not only had a high loading capacity for anticoagulant drugs (on-demand adjustable) but also could achieve effective and sustained anticoagulant function until the SF material was completely degraded.

ACS Applied Materials & InterfacesVol. 17(12)
Soochow University (CN), Bangladesh University of Textiles (BD)
National Natural Science Foundation of China
Openalex Percentile: Top 10%
Silk-based biomaterials and applications
2.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.