Nuclear fuel imaging using position-sensitive detectors

Abstract We are evaluating the performance of a Passive Gamma Emission Tomography (PGET) device [1] equipped with 3D position-sensitive cadmium zinc telluride (CZT) gamma-ray detectors when used for inspecting spent nuclear fuel assemblies (SFAs). Before their disposal in a geological repository, SFAs undergo verification using the PGET device, which was developed under the guidance of the IAEA and approved by the IAEA for safeguards inspections. Recent advancements in imaging detector technology may offer a method to extend the capabilities of such devices beyond standard safeguards applications, allowing an efficient non-invasive way to accurately characterise the properties of nuclear fuel assemblies. The efficiency of the currently used small CZT detectors is restricted by the limited likelihood of full gamma-ray absorption, which is needed for optimal imaging information. Employing larger CZT detectors would increase the probability of capturing the full energy of gamma rays, thereby enhancing the sensitivity of the PGET device and the quality of the reconstructed images. Large CZT detectors need to be position-sensitive to determine through which collimator slit a gamma ray travelled. Position sensitivity results from the pixelated readout of the CZT crystals. Pixelation potentially increases the spatial resolution of the system, which is currently determined by the collimator used. Pixelation allows resolving the position of arrival up to (readout pitch)/√(12). We are additionally exploring the potential of utilising Compton imaging to provide information on the origin of gamma rays along the SFA. Monte Carlo simulations are used to estimate the increase in full photon absorption efficiency when comparing large and current, small, crystals. A dedicated simulation is created using Geant4, where gamma rays of energy 661.7 keV and 1274 keV are targeted to the model describing the approved apparatus now equipped with 22 mm × 22 mm × 10 mm crystals of CZT. It is observed that the efficiency for photon absorption in this case is greatly increased when compared to the existing detectors.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-03-01
DOI
https://doi.org/10.1088/1748-0221/20/03/c03012
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nuclear fuel imaging using position-sensitive detectors

E. Brücken, P. Dendooven, Mounia Laassiri, Santeri Saariokari
Journal of Instrumentation
Radiation Detection and Scintillator Technologies
article

Nuclear fuel imaging using position-sensitive detectors

E. Brücken, P. Dendooven, Mounia Laassiri, Santeri Saariokari
article en

Abstract

Abstract We are evaluating the performance of a Passive Gamma Emission Tomography (PGET) device [1] equipped with 3D position-sensitive cadmium zinc telluride (CZT) gamma-ray detectors when used for inspecting spent nuclear fuel assemblies (SFAs). Before their disposal in a geological repository, SFAs undergo verification using the PGET device, which was developed under the guidance of the IAEA and approved by the IAEA for safeguards inspections. Recent advancements in imaging detector technology may offer a method to extend the capabilities of such devices beyond standard safeguards applications, allowing an efficient non-invasive way to accurately characterise the properties of nuclear fuel assemblies. The efficiency of the currently used small CZT detectors is restricted by the limited likelihood of full gamma-ray absorption, which is needed for optimal imaging information. Employing larger CZT detectors would increase the probability of capturing the full energy of gamma rays, thereby enhancing the sensitivity of the PGET device and the quality of the reconstructed images. Large CZT detectors need to be position-sensitive to determine through which collimator slit a gamma ray travelled. Position sensitivity results from the pixelated readout of the CZT crystals. Pixelation potentially increases the spatial resolution of the system, which is currently determined by the collimator used. Pixelation allows resolving the position of arrival up to (readout pitch)/√(12). We are additionally exploring the potential of utilising Compton imaging to provide information on the origin of gamma rays along the SFA. Monte Carlo simulations are used to estimate the increase in full photon absorption efficiency when comparing large and current, small, crystals. A dedicated simulation is created using Geant4, where gamma rays of energy 661.7 keV and 1274 keV are targeted to the model describing the approved apparatus now equipped with 22 mm × 22 mm × 10 mm crystals of CZT. It is observed that the efficiency for photon absorption in this case is greatly increased when compared to the existing detectors.

Journal of InstrumentationVol. 20(03)
University of Helsinki (FI), Helsinki Institute of Physics (FI)
Nordic Nuclear Safety Research
Openalex Percentile: Top 94%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.