Examining the test–retest reliability of commonly used neuromuscular, morphological, and functional measures in aging adults

The present study aimed at determining the test-retest reliability of commonly used measures in a sample of middle-aged and older participants who presented with a wide range of functional abilities. Participants were middle-aged (40-55 years) and older adults (> 60 years) with- and without mobility limitations, tested both before and after a 4-week period (n = 43). Measures included maximal dynamic (1-RM) and isometric strength, surface EMG (sEMG), peak power, ultrasound-derived muscle size and quality, as well as the performance on the 30-s sit-to-stand, habitual and maximal gait speed, timed up-and-go, stair climb, and 6-min walk tests. Reliability was assessed by means of the intraclass correlation coefficient (ICC), the standard error of measurement (SEM), the minimal detectable change (MDC), and the coefficient of variation (CV). Both dynamic and isometric strength measures displayed excellent reliability (ICCs = 0.96-0.99; CV = 2.2%-7%), whereas muscle size and quality (ICCs = 0.88-0.98; CV = 3.3%-8.7%), functional performance (ICCs = 0.78-0.92; CV = 4.2%-6.8%) and peak power (ICCs = 0.76-0.98; CV = 6.6%-12.8%) results showed good to excellent reliability. Peak power at 80-90% 1‑RM and sEMG measures, on the other hand, showed larger absolute error (CV = 14.4%-18.3% and CV = 14.3%-19.8%, respectively), despite good relative reliability (ICCs = 0.85-0.86). Further results include the comparison between the three subsets of participants included. Our main analysis suggests that most of these measures are sufficiently reliable, even when the two tests are performed a month apart from each other. Our study also supports the notion that, provided that the same equipment and procedures are used, the test-retest reliability of the measures is mostly comparable between the subsets of participants investigated.

Authors

Institutions

Publication Details

Journal
GeroScience
Published
2025-03-11
DOI
https://doi.org/10.1007/s11357-025-01590-0
Citations
1
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
4.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Examining the test–retest reliability of commonly used neuromuscular, morphological, and functional measures in aging adults

Gabriela Barreto David, Robert Csapo, Luana Siqueira Andrade, Gustavo Z. Schaun et al.
1 citations
GeroScience
Balance, Gait, and Falls Prevention
4.76
article

Examining the test–retest reliability of commonly used neuromuscular, morphological, and functional measures in aging adults

Gabriela Barreto David, Robert Csapo, Luana Siqueira Andrade, Gustavo Z. Schaun, Stéphanie Santana Pinto, Cristine Lima Alberton, Eduardo Frio Marins, Peter Raidl, Mariana Silva
article en
1 citations

Abstract

The present study aimed at determining the test-retest reliability of commonly used measures in a sample of middle-aged and older participants who presented with a wide range of functional abilities. Participants were middle-aged (40-55 years) and older adults (> 60 years) with- and without mobility limitations, tested both before and after a 4-week period (n = 43). Measures included maximal dynamic (1-RM) and isometric strength, surface EMG (sEMG), peak power, ultrasound-derived muscle size and quality, as well as the performance on the 30-s sit-to-stand, habitual and maximal gait speed, timed up-and-go, stair climb, and 6-min walk tests. Reliability was assessed by means of the intraclass correlation coefficient (ICC), the standard error of measurement (SEM), the minimal detectable change (MDC), and the coefficient of variation (CV). Both dynamic and isometric strength measures displayed excellent reliability (ICCs = 0.96-0.99; CV = 2.2%-7%), whereas muscle size and quality (ICCs = 0.88-0.98; CV = 3.3%-8.7%), functional performance (ICCs = 0.78-0.92; CV = 4.2%-6.8%) and peak power (ICCs = 0.76-0.98; CV = 6.6%-12.8%) results showed good to excellent reliability. Peak power at 80-90% 1‑RM and sEMG measures, on the other hand, showed larger absolute error (CV = 14.4%-18.3% and CV = 14.3%-19.8%, respectively), despite good relative reliability (ICCs = 0.85-0.86). Further results include the comparison between the three subsets of participants included. Our main analysis suggests that most of these measures are sufficiently reliable, even when the two tests are performed a month apart from each other. Our study also supports the notion that, provided that the same equipment and procedures are used, the test-retest reliability of the measures is mostly comparable between the subsets of participants investigated.

GeroScienceVol. 47(3)
University of Vienna (AT), Universidade Federal de Pelotas (BR)
Universität Wien, Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul
Openalex Percentile: Top 9%
Balance, Gait, and Falls Prevention
4.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.