Reconfigurable Glass Scintillation Screen for Conformal X‐Ray Imaging of Shape‐Changeable Objects

Abstract As the kernel component of X‐ray imaging systems, the mainstream flat‐panel detectors suffer from image distortion and blurring when applied to irregular shaped objects, because of the non‐conformal collocation between the detector and the object. Herein, by taking advantage of the robust glass‐forming capability and versatile processability of (TPT) 2 MnBr 4 (TPT = propyltriphenylphosphonium) scintillator, reconfigurable scintillation screen for conformal X‐ray imaging is explored. Compared to the flexible polymer screens doped with micro‐/nanoparticles, the melt‐casted large‐area (20 × 20 cm 2 ) scintillation screens are homogeneous and immune to light scattering, thus manifesting optical transmittance of above 80% in the 525−800 nm range and high spatial resolution of 25.5 lp mm −1 . More impressively, the screen can be reconfigured in shape near its glass transition temperature, realizing continuous conformance with irregular or changeable objects. Exemplified by conformal X‐ray imaging of a flexed elbow joint and a flexible circuit with variational shapes, the reconfigurable screens demonstrate superiorities in both image clarity (15 lp mm −1 versus 3 lp mm −1 for the conformal imaging versus non‐conformal imaging) and reduction of radiation dosage. That, plus the scalable fabrication process and cost‐effective raw materials, will promise reconfigurable glass scintillation screens great potential in customized medical diagnostics and industrial inspection.

Authors

Institutions

Publication Details

Journal
Laser & Photonics Review
Published
2025-02-23
DOI
https://doi.org/10.1002/lpor.202500266
Citations
7
Primary Topic
3D Shape Modeling and Analysis
Type
article
Field-Weighted Citation Impact
9.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reconfigurable Glass Scintillation Screen for Conformal X‐Ray Imaging of Shape‐Changeable Objects

Shuangyue Cui, Chao Ge, Xiaoxin Zheng, Yuhai Zhang et al.
7 citations
Laser & Photonics Review
3D Shape Modeling and Analysis
9.34
article

Reconfigurable Glass Scintillation Screen for Conformal X‐Ray Imaging of Shape‐Changeable Objects

Shuangyue Cui, Chao Ge, Xiaoxin Zheng, Yuhai Zhang, Xutang Tao, Qinglian Lin, Jiashuai Chen, Xin Ye, Yang Liu, Huimin Li, Shu‐wen Wang, Leilei Zhang, Cuicui Li, Qing Guo, Quanxiang Han, Jinke Jiang, Xingchu Mao
article en
7 citations

Abstract

Abstract As the kernel component of X‐ray imaging systems, the mainstream flat‐panel detectors suffer from image distortion and blurring when applied to irregular shaped objects, because of the non‐conformal collocation between the detector and the object. Herein, by taking advantage of the robust glass‐forming capability and versatile processability of (TPT) 2 MnBr 4 (TPT = propyltriphenylphosphonium) scintillator, reconfigurable scintillation screen for conformal X‐ray imaging is explored. Compared to the flexible polymer screens doped with micro‐/nanoparticles, the melt‐casted large‐area (20 × 20 cm 2 ) scintillation screens are homogeneous and immune to light scattering, thus manifesting optical transmittance of above 80% in the 525−800 nm range and high spatial resolution of 25.5 lp mm −1 . More impressively, the screen can be reconfigured in shape near its glass transition temperature, realizing continuous conformance with irregular or changeable objects. Exemplified by conformal X‐ray imaging of a flexed elbow joint and a flexible circuit with variational shapes, the reconfigurable screens demonstrate superiorities in both image clarity (15 lp mm −1 versus 3 lp mm −1 for the conformal imaging versus non‐conformal imaging) and reduction of radiation dosage. That, plus the scalable fabrication process and cost‐effective raw materials, will promise reconfigurable glass scintillation screens great potential in customized medical diagnostics and industrial inspection.

Laser & Photonics ReviewVol. 19(11)
Qilu University of Technology (CN), Shandong University (CN), University of Jinan (CN), Beijing University of Technology (CN), Naval Aeronautical and Astronautical University (CN), State Key Laboratory of Crystal Materials
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Natural Science Foundation of Shandong Province, National Key Research and Development Program of China
Openalex Percentile: Top 2%
3D Shape Modeling and Analysis
9.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.