Interval Load Flow for Islanded AC and Hybrid AC/DC Microgrids With Load Uncertainties

The islanded mode of AC and hybrid AC/DC microgrids enhances the reliability and resiliency of distribution systems by enabling the use of local Distributed Generators (DGs) during abnormal conditions such as grid faults, weather events, and cyber attacks. Islanded AC Microgrids (IMGs) and Islanded Hybrid AC/DC microgrids (IHMGs) require a specialized modeling approach compared to grid-connected microgrids due to the implementation of droop control for DGs, where active power is regulated through frequency (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\omega$</tex-math></inline-formula>) and reactive power through bus voltage (V). In IHMGs, power sharing among DGs in the DC microgrid is controlled through their respective bus voltages, while the power exchange between AC and DC microgrids is managed using Interlinking Converter (IC). The IC droop control uses the AC microgrid frequency and DC bus voltages for power balance in IHMG. This droop control is modeled using droop equations for system studies. This article presents interval load flow models that account for the unique features of droop control and islanded operation. The integration of renewable energy sources, electric vehicles, storage, and power electronic loads introduces uncertainty in the load demands of IMGs and IHMGs, which are treated as interval quantities, with load flow models solved as optimization problems. The solutions of the interval load flow models for IMGs and IHMGs are validated by comparing them with results from Monte Carlo Simulation studies (MCS). Through various case studies on IMGs and IHMGs, the scalability and efficacy of the interval approach for managing load uncertainty in these microgrids has been demonstrated.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industry Applications
Published
2025-03-11
DOI
https://doi.org/10.1109/tia.2025.3550099
Citations
2
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
2.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interval Load Flow for Islanded AC and Hybrid AC/DC Microgrids With Load Uncertainties

Biswarup Das, Kandukuri Surendra, Vinay Pant
2 citations
IEEE Transactions on Industry Applications
Microgrid Control and Optimization
2.43
article

Interval Load Flow for Islanded AC and Hybrid AC/DC Microgrids With Load Uncertainties

Biswarup Das, Kandukuri Surendra, Vinay Pant
article en
2 citations

Abstract

The islanded mode of AC and hybrid AC/DC microgrids enhances the reliability and resiliency of distribution systems by enabling the use of local Distributed Generators (DGs) during abnormal conditions such as grid faults, weather events, and cyber attacks. Islanded AC Microgrids (IMGs) and Islanded Hybrid AC/DC microgrids (IHMGs) require a specialized modeling approach compared to grid-connected microgrids due to the implementation of droop control for DGs, where active power is regulated through frequency (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\omega$</tex-math></inline-formula>) and reactive power through bus voltage (V). In IHMGs, power sharing among DGs in the DC microgrid is controlled through their respective bus voltages, while the power exchange between AC and DC microgrids is managed using Interlinking Converter (IC). The IC droop control uses the AC microgrid frequency and DC bus voltages for power balance in IHMG. This droop control is modeled using droop equations for system studies. This article presents interval load flow models that account for the unique features of droop control and islanded operation. The integration of renewable energy sources, electric vehicles, storage, and power electronic loads introduces uncertainty in the load demands of IMGs and IHMGs, which are treated as interval quantities, with load flow models solved as optimization problems. The solutions of the interval load flow models for IMGs and IHMGs are validated by comparing them with results from Monte Carlo Simulation studies (MCS). Through various case studies on IMGs and IHMGs, the scalability and efficacy of the interval approach for managing load uncertainty in these microgrids has been demonstrated.

IEEE Transactions on Industry ApplicationsVol. 61(5)
Indian Institute of Technology Roorkee (IN)
Life below water
Openalex Percentile: Top 13%
Microgrid Control and Optimization
2.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Interval Load Flow for Islanded AC and Hybrid AC/DC Microgrids With Load Uncertainties — Biswarup Das, Kandukuri Surendra, et al. · IEEE Transactions on Industry Applications (2025) | TGRS Research Map | TGRS