Development of a 10–50-W Plasma Jet at 10 GHz

This article presents the design, development, and characterization of a plasma jet operating at 10 GHz, covering input power levels from 10 to 50 W. This work builds upon an established microwave plasma device development workflow, adapted for higher frequencies, and demonstrates its feasibility at four times the conventional frequency (2.45 GHz). Utilizing novel Hot-S measuring equipment spanning from 6 to 18 GHz, this article showcases the benefits of operating at higher frequencies. A compact plasma formation with minimal spatial expansion is observed that scales linearly with frequency above the plasma frequency, indicating improved efficiency and control over the plasma jet’s behavior. The length of the plasma increases by approximately 0.6 times relative to input power, while the width remains almost constant, suggesting optimal performance across the studied power range. Furthermore, temperature measurements using a ceramic cannula provide the temperature generated by the plasma.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Plasma Science
Published
2025-03-11
DOI
https://doi.org/10.1109/tps.2025.3546028
Citations
2
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a 10–50-W Plasma Jet at 10 GHz

Christoph Schopp, H. Ziegler, Holger Heuermann
2 citations
IEEE Transactions on Plasma Science
Plasma Diagnostics and Applications
1.46
article

Development of a 10–50-W Plasma Jet at 10 GHz

Christoph Schopp, H. Ziegler, Holger Heuermann
article en
2 citations

Abstract

This article presents the design, development, and characterization of a plasma jet operating at 10 GHz, covering input power levels from 10 to 50 W. This work builds upon an established microwave plasma device development workflow, adapted for higher frequencies, and demonstrates its feasibility at four times the conventional frequency (2.45 GHz). Utilizing novel Hot-S measuring equipment spanning from 6 to 18 GHz, this article showcases the benefits of operating at higher frequencies. A compact plasma formation with minimal spatial expansion is observed that scales linearly with frequency above the plasma frequency, indicating improved efficiency and control over the plasma jet’s behavior. The length of the plasma increases by approximately 0.6 times relative to input power, while the width remains almost constant, suggesting optimal performance across the studied power range. Furthermore, temperature measurements using a ceramic cannula provide the temperature generated by the plasma.

IEEE Transactions on Plasma ScienceVol. 53(4)
FH Aachen (DE)
Affordable and clean energy
Openalex Percentile: Top 19%
Plasma Diagnostics and Applications
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.