An Embedded Auto-Calibrated Offset Current Compensation Technique for PPG/fNIRS System

Optical sensors play a critical role in biomedical monitoring systems, enabling non-invasive measurement of physiological parameters. However, these systems face a persistent challenge: the small amplitude of physiological signals is often overshadowed by a dominant DC offset current. This offset combines the dark current, ambient light, and reflections from fat and skull. This limits the amplification of signals and degrades the sensitivity of PPG/fNIRS systems. This letter presents a mixed-signal auto-calibrated offset compensation technique using dual discrete loops for PPG and fNIRS systems. Two specialized prototypes -a dedicated PPG system and an fNIRS system -were validated using a 3.3 V supply. The results show that the proposed system can effectively compensate for the offset currents within a range of 1lA to 100 lA. We have recorded PPG and fNIRS signals and performed breathing experiments to validate the results. The results show that the proposed system is able to record the signal accurately.

Authors

Institutions

Publication Details

Journal
IEEE Embedded Systems Letters
Published
2025-03-11
DOI
https://doi.org/10.1109/les.2025.3550393
Citations
1
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Embedded Auto-Calibrated Offset Current Compensation Technique for PPG/fNIRS System

Shufali Ashraf Wani, Laxmeesha Somappa, Priyadarshini Padhi, Meraj Ahmad et al.
1 citations
IEEE Embedded Systems Letters
Fault Detection and Control Systems
1.21
article

An Embedded Auto-Calibrated Offset Current Compensation Technique for PPG/fNIRS System

Shufali Ashraf Wani, Laxmeesha Somappa, Priyadarshini Padhi, Meraj Ahmad, Shahid Malik, Sadan Saquib Khan
article en
1 citations

Abstract

Optical sensors play a critical role in biomedical monitoring systems, enabling non-invasive measurement of physiological parameters. However, these systems face a persistent challenge: the small amplitude of physiological signals is often overshadowed by a dominant DC offset current. This offset combines the dark current, ambient light, and reflections from fat and skull. This limits the amplification of signals and degrades the sensitivity of PPG/fNIRS systems. This letter presents a mixed-signal auto-calibrated offset compensation technique using dual discrete loops for PPG and fNIRS systems. Two specialized prototypes -a dedicated PPG system and an fNIRS system -were validated using a 3.3 V supply. The results show that the proposed system can effectively compensate for the offset currents within a range of 1lA to 100 lA. We have recorded PPG and fNIRS signals and performed breathing experiments to validate the results. The results show that the proposed system is able to record the signal accurately.

IEEE Embedded Systems LettersVol. 18(1)
Indian Institute of Technology Bombay (IN), Kelvin Nanotechnology (United Kingdom) (GB), Indian Institute of Technology Delhi (IN), University of Glasgow (GB)
Science and Engineering Research Board
Openalex Percentile: Top 24%
Fault Detection and Control Systems
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.