The Grid-Connected Inverter Stability Enhancement Control Based on Impedance Instability Region Elimination

The weak grid and high phase-locked loop (PLL) bandwidth can easily cause instability issues in the grid-connected Inverter (GCI) system. The present methods mainly enhance system stability by increasing the magnitude and phase of the GCI output impedance, but it cannot completely eliminate the “negative impedance” behavior of the GCI. It means that there is still a risk of instability in the system. Therefore, this article aims to propose a more general stability analysis method, revealing the instability conditions under negative impedance and providing a new insight for stability analysis and control strategy design. First, this article considers the broadband oscillation characteristics exhibited during GCI instability and proposes a new stability analysis method. This method indicates that the system instability is caused by the interaction between fundamental voltage and nonfundamental voltage. This interaction can exacerbate the oscillation of system voltage, ultimately leading to instability issues. This method provides a clear physical explanation for the mechanism of system instability. Second, a new impedance-based stability discrimination method is obtained, determining the conditions for GCI instability. This method can provide a clearer explanation of the present instability phenomena. Then, a compensation method based on <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">q</i>-axis voltage is proposed. This method achieves complete decoupling between the GCI impedance and voltage, effectively eliminating the instability region. Compared with existing methods, the method proposed can better ensure the stability of GCI under weak grid and high PLL bandwidth. Finally, the effectiveness of the proposed methods is verified through simulations and experiments.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2025-03-11
DOI
https://doi.org/10.1109/tpel.2025.3550310
Citations
9
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
4.79

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Grid-Connected Inverter Stability Enhancement Control Based on Impedance Instability Region Elimination

Dashuang Li, Zhengqi Sui, Peng Wang, Rui Wang et al.
9 citations
IEEE Transactions on Power Electronics
Power Systems and Renewable Energy
4.79
article

The Grid-Connected Inverter Stability Enhancement Control Based on Impedance Instability Region Elimination

Dashuang Li, Zhengqi Sui, Peng Wang, Rui Wang, Qiuye Sun
article en
9 citations

Abstract

The weak grid and high phase-locked loop (PLL) bandwidth can easily cause instability issues in the grid-connected Inverter (GCI) system. The present methods mainly enhance system stability by increasing the magnitude and phase of the GCI output impedance, but it cannot completely eliminate the “negative impedance” behavior of the GCI. It means that there is still a risk of instability in the system. Therefore, this article aims to propose a more general stability analysis method, revealing the instability conditions under negative impedance and providing a new insight for stability analysis and control strategy design. First, this article considers the broadband oscillation characteristics exhibited during GCI instability and proposes a new stability analysis method. This method indicates that the system instability is caused by the interaction between fundamental voltage and nonfundamental voltage. This interaction can exacerbate the oscillation of system voltage, ultimately leading to instability issues. This method provides a clear physical explanation for the mechanism of system instability. Second, a new impedance-based stability discrimination method is obtained, determining the conditions for GCI instability. This method can provide a clearer explanation of the present instability phenomena. Then, a compensation method based on <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">q</i>-axis voltage is proposed. This method achieves complete decoupling between the GCI impedance and voltage, effectively eliminating the instability region. Compared with existing methods, the method proposed can better ensure the stability of GCI under weak grid and high PLL bandwidth. Finally, the effectiveness of the proposed methods is verified through simulations and experiments.

IEEE Transactions on Power ElectronicsVol. 40(7)
Nanjing Normal University (CN), Northeastern University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 5%
Power Systems and Renewable Energy
4.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.