Inter‐Day Grasping Model Generalization for Prosthetic Hand Using Soft Optical Sensing Sleeve
Inter‐day motion intent recognition using wearable sensors, due to the change in position during multiple donning and doffing, i.e., surface electromyography, remains a challenge. Herein, an optimal optical sensing sleeve using a multilayer perceptron is introduced to achieve an accurate inter‐day motion intent recognition. This sleeve, demonstrating a high correlation ( R 2 = 0.93) with grasping force, incorporates six novel optical waveguides. Each waveguide is specifically designed to respond to pressing with high linearity, achieved by minimizing bending with a 3D‐printed base and limiting elongation through carbon fiber reinforcement. This novel configuration enhances the generalization of the optical waveguides across multiple donning and doffing sessions. Furthermore, the multilayer perceptron model, which maps sensing signals to grasping forces, shows optimal performance compared to linear, quadratic, cubic, and quartic polynomial models. Remarkably, the correlation in mapping does not decrease in inter‐day experiments; instead, it increases by 4.54%, indicating improved model generalization. Additionally, 12 commonly used items are grasped and held by a prosthetic hand, controlled by the optical sensing sleeve, which suggests the robustness in daily life, for an amputee. The optimal optical sensing sleeve holds promise for contributing to advancements in other wearable robots and achieving an inter‐day model generalization.
Authors
- Fuzhen Yuan
- Linhang Ju (ORCID: https://orcid.org/0000-0003-4584-7726)
- Wuxiang Zhang (ORCID: https://orcid.org/0000-0001-6141-3368)
- Yu Zhao (ORCID: https://orcid.org/0000-0001-8797-8498)
- Yanggang Feng (ORCID: https://orcid.org/0000-0001-6161-3394)
- Di Shi (ORCID: https://orcid.org/0000-0003-3660-2305)
- Yan Huang (ORCID: https://orcid.org/0000-0002-7453-676X)
- Hanze Jia (ORCID: https://orcid.org/0000-0002-9838-0595)
- Ding Xilun
- Yixin Shao (ORCID: https://orcid.org/0000-0002-3773-2542)
- Yanjun Shi (ORCID: https://orcid.org/0009-0002-2096-6032)
Institutions
- Beijing Institute of Technology (CN)
- Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
- Peking University (CN)
- Peking Union Medical College Hospital (CN)
- Peking University Third Hospital (CN)
- Beihang University (CN)
Publication Details
- Journal
- Advanced Intelligent Systems
- Published
- 2025-03-02
- DOI
- https://doi.org/10.1002/aisy.202400569
- Primary Topic
- Muscle activation and electromyography studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Key Technologies Research and Development Program of Anhui Province
- National Natural Science Foundation of China
- Beijing Institute of Technology
- Peking Union Medical College Hospital
- Fundamental Research Funds for the Central Universities