Microwave-based stroke detection system: an experimental investigation of brain tissue volume, composition, and motion artifacts

Abstract Microwave detection is a prospective method in promptly identifying strokes, thereby facilitating clinical intervention and improved prognosis. We aimed to explore the factors affecting microwave stroke detection results, including brain tissue volume, composition, and motion artifacts. Various brain tissue conductivities were simulated using different concentrations of sodium chloride solutions. Physical experiments were conducted utilizing a microwave detection system, with observations focused on changes in S -parameters. Eigenvalue changes are most notable for volume alterations and motion artifacts. The eigenvalues of motion artifacts and volumes exhibit distinctions at specific frequencies. At 1.85 GHz, differences in the imaginary part of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mrow> <mml:msub> <mml:mi>S</mml:mi> <mml:mrow> <mml:mn>11</mml:mn> </mml:mrow> </mml:msub> </mml:mrow> </mml:mrow> </mml:math> depend solely on volume variation. The study reveals that volume changes and motion artifacts significantly impact microwave detection outcomes. Motion artifacts can be initially mitigated by targeting specific frequency points. The optimal eigenvalues for characterizing volume changes are differences in imaginary parts of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mrow> <mml:msub> <mml:mi>S</mml:mi> <mml:mrow> <mml:mn>11</mml:mn> </mml:mrow> </mml:msub> </mml:mrow> </mml:mrow> </mml:math> , and real parts of differences in <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mrow> <mml:msub> <mml:mi>S</mml:mi> <mml:mrow> <mml:mn>21</mml:mn> </mml:mrow> </mml:msub> </mml:mrow> </mml:mrow> </mml:math> serve as the optimal feature for characterizing composition changes.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2025-03-11
DOI
https://doi.org/10.1088/1361-6501/adbf36
Citations
1
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microwave-based stroke detection system: an experimental investigation of brain tissue volume, composition, and motion artifacts

Zelin Bai, Mingsheng Chen, Lilong Zhou, Wei Zhuang et al.
1 citations
Measurement Science and Technology
Optical Imaging and Spectroscopy Techniques
1.36
article

Microwave-based stroke detection system: an experimental investigation of brain tissue volume, composition, and motion artifacts

Zelin Bai, Mingsheng Chen, Lilong Zhou, Wei Zhuang, Jie Liu, Weiheng Cui, Hang Deng, Haisheng Zhang
article en
1 citations

Abstract

Abstract Microwave detection is a prospective method in promptly identifying strokes, thereby facilitating clinical intervention and improved prognosis. We aimed to explore the factors affecting microwave stroke detection results, including brain tissue volume, composition, and motion artifacts. Various brain tissue conductivities were simulated using different concentrations of sodium chloride solutions. Physical experiments were conducted utilizing a microwave detection system, with observations focused on changes in S -parameters. Eigenvalue changes are most notable for volume alterations and motion artifacts. The eigenvalues of motion artifacts and volumes exhibit distinctions at specific frequencies. At 1.85 GHz, differences in the imaginary part of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mrow> <mml:msub> <mml:mi>S</mml:mi> <mml:mrow> <mml:mn>11</mml:mn> </mml:mrow> </mml:msub> </mml:mrow> </mml:mrow> </mml:math> depend solely on volume variation. The study reveals that volume changes and motion artifacts significantly impact microwave detection outcomes. Motion artifacts can be initially mitigated by targeting specific frequency points. The optimal eigenvalues for characterizing volume changes are differences in imaginary parts of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mrow> <mml:msub> <mml:mi>S</mml:mi> <mml:mrow> <mml:mn>11</mml:mn> </mml:mrow> </mml:msub> </mml:mrow> </mml:mrow> </mml:math> , and real parts of differences in <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mrow> <mml:msub> <mml:mi>S</mml:mi> <mml:mrow> <mml:mn>21</mml:mn> </mml:mrow> </mml:msub> </mml:mrow> </mml:mrow> </mml:math> serve as the optimal feature for characterizing composition changes.

Measurement Science and TechnologyVol. 36(4)
Army Medical University (CN), Chongqing University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 23%
Optical Imaging and Spectroscopy Techniques
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.