Heat transfer regimes and critical heat flux during spray cooling with subcooled water
The results of an experimental investigation on heat transfer and critical heat flux during surface cooling with a dispersed flow of deeply subcooled liquid are presented. The study was carried out using a pressure nozzle with a mass flow rate of water of 24.2 g/s. A record critical heat flux of 13.2 MW/m2 was achieved in these experiments. The findings indicate that the onset of boiling within the liquid film formed on the impact surface during spraying leads to a notable reduction in the temperature non-uniformity across the heater.
Authors
- А. Д. Назаров (ORCID: https://orcid.org/0000-0002-3159-7255)
- И. В. Владыко (ORCID: https://orcid.org/0000-0002-9652-3441)
- Nikolay B. Miskiv (ORCID: https://orcid.org/0000-0002-5608-5563)
- Anton Surtaev (ORCID: https://orcid.org/0000-0001-7214-1046)
- А. Н. Павленко (ORCID: https://orcid.org/0000-0002-8610-6951)
- A. V. Mikhaĭlov
Institutions
- Novosibirsk State University (RU)
- Institute of Thermophysics (RU)
Publication Details
- Journal
- Thermophysics and Aeromechanics
- Published
- 2025-03-11
- DOI
- https://doi.org/10.1134/s0869864324040127
- Primary Topic
- Fluid Dynamics and Heat Transfer
- Type
- article
- Field-Weighted Citation Impact
- 0.00