Modeling of a BK7 prism/Ag/Ni/ZnSe/SM-based sensor for maintaining optimum performance in glucose level detection

Patients suffering from diabetes, or having problems regarding up-downs in glucose levels may need to prick human skin to draw blood samples for checkups. Due to the enhancement of photonics, surface plasmon resonance(SPR) is a relief to them. As of now glucose levels can be detected from urine instead of blood. This research delves into the characterization of an SPR sensor combining a prism-coupled Silver (Ag), Nickel (Ni), and Zinc Selenide (ZnSe) hybrid modeled structure to maintain overall enhanced performance for the detection of glucose concentrations of the patients in urine samples. The motivation is to develop an optimum resulting surface plasmon resonance sensor for this issue based on the Kretschmann configuration. In the present work, the standard transfer matrix method and the Fresnel formulations were utilized to investigate this study. The proposed biosensor comprises nickel (Ni) and zinc selenide (ZnSe), which improves the sensitivity of the surface plasmon resonance-based sensor and protects Ag from being oxidized. The findings reveal high-overall performance parameters are a sensitivity of 329.21 degrees/RIU, full width at half maximum of 3.89 (degrees), a figure of merit of 84.489398, a quality factor of 84.575835 (1/RIU), and a detection accuracy of 0.2570694 (1/degree) for the BK7 prism/Ag/Ni/ZnSe/sensing medium configuration at a wavelength of 633 nm. The exalted performance of this biosensor is efficient in detecting the concentration level of different liquid analytes in biosensing platforms, offering significant promise for the analysis of glucose concentration. • A unique modeled cost-effective biosensor using Kretschmann configuration. • Responds to minute changes of 0.001 in the refractive indices of urine samples. • Provides optimized parameters ensuring high performance. • The study elaborates on the reason for selecting each layer. • Presents the outcomes of changing the thickness of different layers.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics X
Published
2025-03-12
DOI
https://doi.org/10.1016/j.biosx.2025.100604
Citations
4
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
3.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling of a BK7 prism/Ag/Ni/ZnSe/SM-based sensor for maintaining optimum performance in glucose level detection

Kazi Mustafizur Rahman
4 citations
Biosensors and Bioelectronics X
Advanced biosensing and bioanalysis techniques
3.22
article

Modeling of a BK7 prism/Ag/Ni/ZnSe/SM-based sensor for maintaining optimum performance in glucose level detection

Kazi Mustafizur Rahman
article en
4 citations

Abstract

Patients suffering from diabetes, or having problems regarding up-downs in glucose levels may need to prick human skin to draw blood samples for checkups. Due to the enhancement of photonics, surface plasmon resonance(SPR) is a relief to them. As of now glucose levels can be detected from urine instead of blood. This research delves into the characterization of an SPR sensor combining a prism-coupled Silver (Ag), Nickel (Ni), and Zinc Selenide (ZnSe) hybrid modeled structure to maintain overall enhanced performance for the detection of glucose concentrations of the patients in urine samples. The motivation is to develop an optimum resulting surface plasmon resonance sensor for this issue based on the Kretschmann configuration. In the present work, the standard transfer matrix method and the Fresnel formulations were utilized to investigate this study. The proposed biosensor comprises nickel (Ni) and zinc selenide (ZnSe), which improves the sensitivity of the surface plasmon resonance-based sensor and protects Ag from being oxidized. The findings reveal high-overall performance parameters are a sensitivity of 329.21 degrees/RIU, full width at half maximum of 3.89 (degrees), a figure of merit of 84.489398, a quality factor of 84.575835 (1/RIU), and a detection accuracy of 0.2570694 (1/degree) for the BK7 prism/Ag/Ni/ZnSe/sensing medium configuration at a wavelength of 633 nm. The exalted performance of this biosensor is efficient in detecting the concentration level of different liquid analytes in biosensing platforms, offering significant promise for the analysis of glucose concentration. • A unique modeled cost-effective biosensor using Kretschmann configuration. • Responds to minute changes of 0.001 in the refractive indices of urine samples. • Provides optimized parameters ensuring high performance. • The study elaborates on the reason for selecting each layer. • Presents the outcomes of changing the thickness of different layers.

Biosensors and Bioelectronics XVol. 24
Ahsanullah University of Science and Technology (BD)
Affordable and clean energy
Openalex Percentile: Top 9%
Advanced biosensing and bioanalysis techniques
3.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modeling of a BK7 prism/Ag/Ni/ZnSe/SM-based sensor for maintaining optimum performance in glucose level detection — Kazi Mustafizur Rahman · Biosensors and Bioelectronics X (2025) | TGRS Research Map | TGRS