Evaluation of a novel compliance-matching aortic graft in a swine model

The mismatch of elastic properties between the arterial tissue and the vascular grafts, commonly called compliance mismatch, is responsible for many deleterious post-operative complications. Currently, there is an absence of prostheses that conform with the compliance of healthy aortas. We aimed to evaluate the in vivo performance of novel compliance-matching grafts in a swine model and compare it to the native aorta and to gold-standard aortic grafts.We proposed a compliance-matching graft design, composed of a standard aortic graft surrounded by an optimized Nickel-Titanium compliance-augmenting layer. We replaced the thoracic aorta of six domestic pigs with compliance-matching grafts under cardiopulmonary bypass. We removed the compliance-regulating layer of the compliant grafts, so that gold-standard grafts remained implanted. The aortic pressure and flow rate were measured at the three stages of the experiment to assess hypertension and arterial stiffness. The compliance-matching grafts were implanted without inducing post-operative hypertension by maintaining systolic pressure (p = 0.26), aortic pulse wave velocity (p = 0.89) and aortic distensibility (p = 0.67) at healthy levels. The gold-standard grafts caused a significant rise in systolic pressure (p = 0.005), pulse wave velocity (p = 0.012) and they approximately doubled pulse pressure (p < 0.001). Our novel compliant grafts could diminish the complications caused by compliance-mismatch and they could surpass the clinical performance of existing prostheses. The proposed grafts comprise a step towards optimized treatment and improved life expectancy of patients subjected to aortic replacement.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2025-03-11
DOI
https://doi.org/10.1016/j.jbiomech.2025.112629
Citations
1
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
1.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a novel compliance-matching aortic graft in a swine model

Mathieu van Steenberghe, Nikolaos Stergiopulos, Philippe Reymond, Walid Habre et al.
1 citations
Journal of Biomechanics
Aortic Disease and Treatment Approaches
1.52
article

Evaluation of a novel compliance-matching aortic graft in a swine model

Mathieu van Steenberghe, Nikolaos Stergiopulos, Philippe Reymond, Walid Habre, Christoph Huber, Georgios Rovas, Mustafa Çıkırıkçıoğlu, Vasiliki Bikia, John Diaper
article en
1 citations

Abstract

The mismatch of elastic properties between the arterial tissue and the vascular grafts, commonly called compliance mismatch, is responsible for many deleterious post-operative complications. Currently, there is an absence of prostheses that conform with the compliance of healthy aortas. We aimed to evaluate the in vivo performance of novel compliance-matching grafts in a swine model and compare it to the native aorta and to gold-standard aortic grafts.We proposed a compliance-matching graft design, composed of a standard aortic graft surrounded by an optimized Nickel-Titanium compliance-augmenting layer. We replaced the thoracic aorta of six domestic pigs with compliance-matching grafts under cardiopulmonary bypass. We removed the compliance-regulating layer of the compliant grafts, so that gold-standard grafts remained implanted. The aortic pressure and flow rate were measured at the three stages of the experiment to assess hypertension and arterial stiffness. The compliance-matching grafts were implanted without inducing post-operative hypertension by maintaining systolic pressure (p = 0.26), aortic pulse wave velocity (p = 0.89) and aortic distensibility (p = 0.67) at healthy levels. The gold-standard grafts caused a significant rise in systolic pressure (p = 0.005), pulse wave velocity (p = 0.012) and they approximately doubled pulse pressure (p < 0.001). Our novel compliant grafts could diminish the complications caused by compliance-mismatch and they could surpass the clinical performance of existing prostheses. The proposed grafts comprise a step towards optimized treatment and improved life expectancy of patients subjected to aortic replacement.

Journal of BiomechanicsVol. 183
University Hospital of Geneva (CH), École Polytechnique Fédérale de Lausanne (CH)
Innosuisse - Schweizerische Agentur für Innovationsförderung
Zero hunger
Openalex Percentile: Top 21%
Aortic Disease and Treatment Approaches
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.