Evaluation of a novel compliance-matching aortic graft in a swine model
The mismatch of elastic properties between the arterial tissue and the vascular grafts, commonly called compliance mismatch, is responsible for many deleterious post-operative complications. Currently, there is an absence of prostheses that conform with the compliance of healthy aortas. We aimed to evaluate the in vivo performance of novel compliance-matching grafts in a swine model and compare it to the native aorta and to gold-standard aortic grafts.We proposed a compliance-matching graft design, composed of a standard aortic graft surrounded by an optimized Nickel-Titanium compliance-augmenting layer. We replaced the thoracic aorta of six domestic pigs with compliance-matching grafts under cardiopulmonary bypass. We removed the compliance-regulating layer of the compliant grafts, so that gold-standard grafts remained implanted. The aortic pressure and flow rate were measured at the three stages of the experiment to assess hypertension and arterial stiffness. The compliance-matching grafts were implanted without inducing post-operative hypertension by maintaining systolic pressure (p = 0.26), aortic pulse wave velocity (p = 0.89) and aortic distensibility (p = 0.67) at healthy levels. The gold-standard grafts caused a significant rise in systolic pressure (p = 0.005), pulse wave velocity (p = 0.012) and they approximately doubled pulse pressure (p < 0.001). Our novel compliant grafts could diminish the complications caused by compliance-mismatch and they could surpass the clinical performance of existing prostheses. The proposed grafts comprise a step towards optimized treatment and improved life expectancy of patients subjected to aortic replacement.
Authors
- Mathieu van Steenberghe (ORCID: https://orcid.org/0000-0001-6329-2280)
- Nikolaos Stergiopulos (ORCID: https://orcid.org/0000-0002-0519-0160)
- Philippe Reymond (ORCID: https://orcid.org/0000-0002-0772-6862)
- Walid Habre (ORCID: https://orcid.org/0000-0002-6521-5091)
- Christoph Huber (ORCID: https://orcid.org/0000-0001-9048-849X)
- Georgios Rovas (ORCID: https://orcid.org/0000-0002-4020-6826)
- Mustafa Çıkırıkçıoğlu (ORCID: https://orcid.org/0000-0003-1143-347X)
- Vasiliki Bikia (ORCID: https://orcid.org/0000-0002-4660-1560)
- John Diaper
Institutions
- University Hospital of Geneva (CH)
- École Polytechnique Fédérale de Lausanne (CH)
Publication Details
- Journal
- Journal of Biomechanics
- Published
- 2025-03-11
- DOI
- https://doi.org/10.1016/j.jbiomech.2025.112629
- Citations
- 1
- Primary Topic
- Aortic Disease and Treatment Approaches
- Type
- article
- Field-Weighted Citation Impact
- 1.52
Funders
- Innosuisse - Schweizerische Agentur für Innovationsförderung