Direct sun total NO2 column measurements at Thessaloniki, Greece with two DOAS systems and comparisons with S5P/TROPOMI
Multiple Multi-Axis Differential Optical Absorption Spectroscopy (MAX-DOAS) instruments have been operating in the Laboratory of Atmospheric Physics (LAP), Thessaloniki, Greece over a decade to monitor trace gases in the troposphere. In this work, we present methodology, applied for the first time in LAP for retrieving total NO 2 columns in the atmosphere by applying the Direct Sun DOAS technique (DS-DOAS) on solar direct radiance spectra acquired with a research grade MAX-DOAS system, Delta. For the retrieval of total NO 2 two spectral fitting methods were tested using cross sections of NO 2 at two different temperatures for the tropospheric and the stratospheric component. The method that is based on concurrent spectral DOAS fittings with NO 2 cross sections at two temperatures (294 K and 220 K) (2T method) produces results of better quality as compared to the method using NO 2 cross section at one 254.5 K (1T method), with latter underestimating the total NO 2 vertical column density by up to 15%. This was verified by the good agreement (correlation coefficient R=0.973) against the total NO 2 columns measured by an independently calibrated collocated Pandora system. Finally, the total NO 2 columns derived from the Delta instrument were compared with collocated observations by S5P/TROPOMI, showing an underestimation of the latter by up to 40% for days with high NO 2 concentrations, while the agreement is better under low NO 2 conditions. The overall agreement between the satellite and Delta system observations is characterized by a correlation coefficient of 0.82 and a mean bias of –2.63 ± 2.75 Pmolec/cm 2 . • A retrieval method was established to obtain the total NO 2 column from direct-sun spectral radiances of a research-grade DOAS system in Thessaloniki, Greece, using NO 2 cross sections at two temperatures (294 K and 220 K). • The retrieval methodology was evaluated by comparison to a collocated Pandora system with a mean difference of -3%. • Based on two years of observations, the TROPOMI instrument onboard the S-5P satellite underestimates the total NO2 column by 21%. • The total NO 2 column at Thessaloniki shows a distinct annual course (higher levels in winter) and ranges from 3 to 35 Pmolec/cm 2 .
Authors
- Dimitris Karagkiozidis
- Dimitrios Nikolis
- Dimitris Balis
- Alkiviadis Bais (ORCID: https://orcid.org/0000-0003-3899-2001)
- Maria-Elissavet Koukouli (ORCID: https://orcid.org/0000-0002-7509-4027)
Institutions
- Hellenic Agency for Local Development and Local Government (GR)
Publication Details
- Journal
- Atmospheric Environment
- Published
- 2025-03-11
- DOI
- https://doi.org/10.1016/j.atmosenv.2025.121161
- Citations
- 2
- Primary Topic
- Atmospheric Ozone and Climate
- Type
- article
- Field-Weighted Citation Impact
- 2.60