ICISE23 - Biometric Recognition on Compressed ECG Signals Under Different Physiological Conditions

In the study, ECG is investigated as a biometric recognition system. To fit in the real-life scenarios, different physiological conditions and signal compression are considered. A total of 9 subjects conducting three simple exercises which are riding bicycle on high resistance, low resistance and walking taken from Physionet. Due to the noise collected during ECG recording process, the contaminated signals are filtered using low pass Butterworth filter. Then, QRS is segmented using Pan Tompkins algorithm. After that, Wavelet Transform is applied to compress the segmented QRS. Classification is done on non-compressed and compressed QRS by using multi-class of SVM to compare its accuracy. The study discovered that, biometric can be performed on compressed signals. The outcome also shows that, Cubic SVM is the proper classification technique to be applied on person verification regardless of different physiological conditions. The accuracy achieved was up to 94.4% for non-compressed signals and 91.7% for compressed signals.

Authors

Institutions

Publication Details

Journal
Journal of Advanced Research in Applied Sciences and Engineering Technology
Published
2024-12-24
DOI
https://doi.org/10.37934/araset.66.2.3447
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ICISE23 - Biometric Recognition on Compressed ECG Signals Under Different Physiological Conditions

Siti Nurfarah Ain Mohd Azam, Khairul Azami Sidek
Journal of Advanced Research in Applied Sciences and Engineering Technology
ECG Monitoring and Analysis
article

ICISE23 - Biometric Recognition on Compressed ECG Signals Under Different Physiological Conditions

Siti Nurfarah Ain Mohd Azam, Khairul Azami Sidek
article en

Abstract

In the study, ECG is investigated as a biometric recognition system. To fit in the real-life scenarios, different physiological conditions and signal compression are considered. A total of 9 subjects conducting three simple exercises which are riding bicycle on high resistance, low resistance and walking taken from Physionet. Due to the noise collected during ECG recording process, the contaminated signals are filtered using low pass Butterworth filter. Then, QRS is segmented using Pan Tompkins algorithm. After that, Wavelet Transform is applied to compress the segmented QRS. Classification is done on non-compressed and compressed QRS by using multi-class of SVM to compare its accuracy. The study discovered that, biometric can be performed on compressed signals. The outcome also shows that, Cubic SVM is the proper classification technique to be applied on person verification regardless of different physiological conditions. The accuracy achieved was up to 94.4% for non-compressed signals and 91.7% for compressed signals.

Journal of Advanced Research in Applied Sciences and Engineering Technology
International Islamic College (MY), International Islamic University Malaysia (MY)
Openalex Percentile: Top 53%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ICISE23 - Biometric Recognition on Compressed ECG Signals Under Different Physiological Conditions — Siti Nurfarah Ain Mohd Azam, Khairul Azami Sidek · Journal of Advanced Research in Applied Sciences and Engineering Technology (2024) | TGRS Research Map | TGRS